  • Page 1 User’ s Manual Argox Handheld Bar Code Scanner Model No.: AS-8510...
  • Page 2 USING AS-8510/8512 RADIO CRADLE The AS-8510/8512 radio cradle paired with one AS-8510/8512 scanner, builds a Cordless Reading System for the collection, decoding and transmission of barcoded data. It can be connected to a Host PC through an RS232, Keyboard wedge or USB cable and is suited for a single-cradle layout.
  • Page 3 Default setting For each barcode shown as below: Read Checksum Checksum Enable Code Code Type Verification Transmission Enable Enable 8510 8512 UPC-A UPC-E EAN-13 EAN-8 Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 V two digits Code-93 &...
  • Page 4 ArgoScan 8510/8512 Specification Model 8510 / 8512 Operational Light Source 635 nm Visible Red LED Optical System 2048 pixel CCD (Charge-coupled device) Depth of Scan Field Up to 600mm (CODE 39, PSC=90%, 20mils) Scanning Width 160mm Scan Speed 400 scans/sec 0.1mm(4mils) Resolution Code39,PCS=90%...
  • Page 5 Case material ABS (over molded at contact pointed) Cushion material Double injection Cradle interface RS232, Keyboard wedge, USB Electrical Input Voltage 5 VDC ± 10% VDC (Cradle) Power - Operating 5 VDC (Cradle) Power – Standby 5 VDC (Cradle) Current – Operating 132 mA (Cradle) Current –...
  • Page 6 Ventilation None required Programming Manual (Reading special barcode) DOS Programming command through RS-232, Windows method configuration program Program upgrade Enabled by built-in flash memory Code type selection, check digit Programmable selection Decoding option Decoding characteristics option Transmitted character delay, Header selection, trailer selection, message suffix, good read beep tone and volume, scanner trigger selection Keyboard emulation type...
  • Page 7 Programming the AS-8510 / 8512 To program the 8510 or 8512, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented.
  • Page 8 Program Barcode Program Option Bar Code Option Alphanumeric Entry Keyboard Wedge Interface RS-232 selection Wand emulation Keyboard/RS-232 Auto detection Reserved Exit Option Barcode Back Fold Out Exit Barcode Finish barcode...
  • Page 9 Interface Selection This decoder built-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulation, and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface.
  • Page 10 Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer.
  • Page 11 Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard”...
  • Page 12 Belgium Keyboard layout Danish France Germany Italian Portuguese Spanish Swedish Switzerland Latin American Japanese 00-08 0 : high clock rate Keyboard speed 8 : low clock rate (8310/8312) Disable Enable Function key Alphabetic key Numeric keypad Numeric key (Num lock state only) Alt+Keypad Exit...
  • Page 13 Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on.
  • Page 14 Program Option Bar Code Option Alphanumeric Entry Caps lock”ON” Caps lock”OFF” Caps lock Disable Enable Power-on simulation 00-99 msec 00-99 Inter-character delay 00-99 10 msec 00-99 Block transmission delay Exit...
  • Page 15 RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 11 Xoff: Transmit Off (ASCII Code13 Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol.
  • Page 16 Program Option Bar Code Option Alphanumeric Entry None RTS/CTS Flow control Xon/Xoff ACK/NAK 00-99 (msec) 00-99 Inter-character delay 00-99 (10 msec) 00-99 Block transmission delay 00-99 (100 msec) 00-99 Response delay Exit...
  • Page 17 Program Option Bar Code Option Alphanumeric Entry 300 BPS 600 BPS Baud rate 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS None Parity Even 8 bits 7 bits Data bit One bit Two bits Stop bit Exit...
  • Page 18 Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning.
  • Page 19 Notes 1): Please set the min/max length if you have special demand for individual barcode. 2): Include the Check sum digits if you want to set Global min/max code length. Program Option Bar Code Option Alphanumeric Entry Good-read off Momentary Scanning mode Alternate Timeout off...
  • Page 20 00-63 00-63 Global min. code length Scan Inverted image scan: Set Enabled the scanner will scan Exit both black/white barcode with white/black background. CTS trigger: This operation enabled an external device to control scanning. The CTS trigger is controlled by apply an external trigger signal to the CTS input.
  • Page 21 Disable Enable Inverted image scan Disable Enable CTS trigger Disable Enable *7AJ* Power saving (For 8310/8312) Disable 30 second Position indication 60 second 90 second 120 second 150 second 180 second Continue LED ‘ ’ on’ ’ LED ‘ ’ off’ ’ *7AL* Stand mode selection (For 8310/8312)
  • Page 22 Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self -test. LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the scanner will beep buzzer to indicate a good barcode reading, and its Beep loudness , Beep tone freq.
  • Page 23 Program Option Bar Code Option Alphanumeric Entry Disable Enable Power on alert Disable Enable LED indication Disable Enable Beeper indication 00-07 00-07 Beep loudness 00-99 (100Hz) 00-99 Beep tone freq. 00-99 (10 msec) 00-99 Beep tone duration Exit...
  • Page 24 UPCA Read: Format Leading Data Digits Check Zero (11 Digits) Digit Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero. It will beep instead of reading anything when the trunc ate value is more than the barcode data digits or the value of Truncate Leading is overlapped with that of...
  • Page 25 Disable Enable Check-sum verification Disable Enable Check-sum transmission 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < A > Code ID setting 00-44 00-44 Insert group selection Exit...
  • Page 26 UPCA Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 characters for WPC code. Format Supplement Digits Leading Data Digits Check 2 or 5 or Zero (11 Digits) Digit UCC / EAN Truncation / Expansion: The leading “0” digits of UPCA data characters can be truncated w hen the function is enabled.
  • Page 27 None 2 digits Supplement digits 5 digits (For 8310/8312) 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 Disable Enable Truncation/ Expansion (For 8110/8210) None Truncate leading Truncation/ zero Expansion (For Expand to EAN13 8150/8310/8312) Exit...
  • Page 28 UPCE Read: Format Leading Data Digits (6 Check Zero Digits) Digits Check -sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check -sum transmission: By setting Enable, checks sum will be transmitted.
  • Page 29 Disable Enable Check-sum transmission 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < E > Code ID setting Exit...
  • Page 30 UPCE Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Supplement Digits Leading Data Digits Check 2 or 5 or Zero (6 Digits) Digit UCC/EAN Expansion: The expansion function is used only for UPCE and EAN-8 code reading. It extends to 13-digits with “0” digits when the feature is enabled.
  • Page 31: Table Of Contents

    None 2 digits Supplement digits 5 digits (For 8310/8312) 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 Disable Enable Truncation/Expansion (For 8110/8210) None Truncate leading Truncation/Expansion zero (For 8150/8310/8312) Expand to EAN13 Expand to UPCA Disable Enable Expansion Disable Enable *OAM*...
  • Page 32 EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check -sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
  • Page 33 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending Exit...
  • Page 34: Digits

    EAN-13 Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (12 Digits) Digits UCC / EAN ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two kinds of barcode for book and magazines.
  • Page 35: (For 8310/8312)

    None 2 digits Supplement digits 5 digits (For 8110/8150/8210) UCC/EAN 128 Auto detection None 2 digits Supplement digits 5 digits (For 8310/8312) 2,5 digits UCC/EAN 128 2, UCC/EAN 5, UCC/EAN Disable Enable ISBN/ISSN conversion Exit...
  • Page 36: Enable

    EAN-8 Read: Format Data Digits Check (7 Digits) Digits Check -sum verification: The checksum of EAN-8 is optional and made as the sum of the numerical value of the data digits. Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
  • Page 37: Truncate Leading

    Disable Enable Check-sum transmission 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending Two characters 00-ffH, 00-ffH 00-ffH ASCII < FF > Code ID setting code 00-44 00-44 Insert group selection Exit...
  • Page 38 EAN-8 Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (7 Digits) Digits UCC/EAN 128 Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE. Program Option Bar Code Option Alphanumeric Entry None 2 digits...
  • Page 39 Disable Enable Truncation / Expansion (For 8110/8210) None Truncate leading Truncation / zero Expansion Expand to EAN13 (For 8150 /8310/8312) Disable Enable Expansion Exit...
  • Page 40 Code 39 Read: Format Start Data Digits Checksum “★” ( Variable) (Optional) “★” Check -sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check -sum transmission: By setting Enable, checksum will be transmitted.
  • Page 41 Disable Enable Read Disable Enable Check-sum verification Disable Enable Check-sum transmission 00-64 00-64 Min. code length 0-20 00-20 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < > Code ID setting Exit...
  • Page 42 Code 39 Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z).
  • Page 43 Standard Full ASCII Format Disable Enable Append Disable Enable Start/end transmission Exit...
  • Page 44 Interleaved 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Check -sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check -sum transmission: By setting Enable, checksum will be transmitted. Max./Min.
  • Page 45 Disable Enable Check-sum transmission 00-64 00-64 Max. code leading 00-64 00-64 Min. code leading 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < i > Code ID setting 00-44 00-44 Insert group selection Exit...
  • Page 46 Industrial 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
  • Page 47 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < i > Code ID setting 00-44 00-44 Insert group selection Exit...
  • Page 48 Matrix 2 of 5 Eur Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min.
  • Page 49 Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < B > Code ID setting 00-44 00- 44 Insert group selection Exit...
  • Page 50 Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 51 Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < % > Code ID setting Exit...
  • Page 52 Codabar Insertion group selection: Refer to Insertion group selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39. Program Option Bar Code Option Alphanumeric...
  • Page 53 Code-128 Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Program Option Bar Code Option Alphanumeric Entry Disable Enable Read Disable...
  • Page 54 Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Code-128 can be translated to UCC/EAN -128 format if it starts with FNC1 character.
  • Page 55 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < # > Code ID setting 00-44 00-44 Insert group selection Standard UCC/EAN-128 Format Exit...
  • Page 56 Code-128 Append: When the function is enabled, it won't show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read the barcode, which doesn't have FNC2 code. UCC/ EAN 128 ID setting: To setting the code ID for UCC/EAN-128 output format.
  • Page 57 Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Program Option Bar Code Option Alphanumeric Entry...
  • Page 58 Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric...
  • Page 59 00-ffH ASCII 00-ffH code < & > Code ID setting 00-44 00-44 Insert group selection Exit...
  • Page 60 Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min.
  • Page 61 Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < O > Code ID setting 00-44 00-44 Insert group selection Exit...
  • Page 62 MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits.
  • Page 63 Mod 11/10 Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < @ > Code ID setting 00-44 00-44 Insert group selection Exit...
  • Page 64 UK/plessey Read: Format Data Digits Checksum1+2 (Variable) (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and chec ksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
  • Page 65 Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < @ > Code ID setting 00-44 00-44 Insert group selection Exit...
  • Page 66 Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 67 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < S > Code ID setting 00-44 00-44 Insert group selection Numeric only Full ASCII only Format Exit...
  • Page 68 Standard 2 of 5 Read: Format Data Digits Checksum1 (Variable) (Optional) Check -sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check -sum transmission: By setting Enable, checksum will be transmitted. Max./Min.
  • Page 69 Disable Enable *JAC* Check-sum transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < i > Code ID setting 00-44 00-44 Insert group selection Exit...
  • Page 70 China Post Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
  • Page 71 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < t > Code ID setting 00-44 01-44 Insert group selection Exit...
  • Page 72 Italian Pharmacode Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
  • Page 73 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 01-ffH code < p > Code ID setting 00-44 00-44 Insert group selection Disable Enable Leading “A” Exit...
  • Page 74 Code-16K Only the 8210 / 8312 can decode Code-16K. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry...
  • Page 75 PDF-417 Only the 8512 can decode PDF-417. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable Enable Read 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending Exit...
  • Page 76 PDF-417 Only the 8512 can decode PDF-417. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00-ffH ASCII 00-ffH code < > Code ID setting 00-44 00-44...
  • Page 77 String setting Prefix characters: Up to 22 ASCII characters may be sent before data digits. Prefix Data Digits Suffix Suffix characters: Up to 22 ASCII characters may be sent after data digits. Program Option Bar Code Option Alphanumeric Entry None 1-22 characters 00-ffH ASCII Prefix characters...
  • Page 78 String setting Preamble/ Postamble characters: They are appended to the data automatically when each barcode is decoded. Example: Add a prefix/suffix or preamble/postamble for all symbologies. In this example, you are sending a $ symbol as a prefix for all symbologies.
  • Page 79 None 1-22 characters 00-ffH ASCII Preamble characters code setting None 1-22 characters 00-ffH ASCII Postamble code characters setting None 1-22 characters 00-ffH ASCII Insert G1 characters code setting None 1-22 characters 00-ffH ASCII Insert G2 characters code setting None 1-22 characters 00-ffH ASCII Insert G3 characters code...
  • Page 80 Transmission Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By setting Enable, Postamble will be appended after the data is transmitted. Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol. The position default value is “00”...
  • Page 81 00-63 00-63 (00: no insertion) Insert data group 1 position 00-63 00-63 (00: no insertion) Insert data group 2 position 00-63 00-63 (00: no insertion) Insert data group 3 position 00-63 00-63 (00: no insertion) Insert data group 4 position Before code data After code data Code ID position...
  • Page 82 Transmission Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected. The total length of the barcode is the number of barcode data except Truncate Leading/Ending Digits.
  • Page 83 Disable Enable Code length transmission Disable Enable Code name transmission Disable Upper case Case conversion Lower case *For barcode data only Exit Format of barcode data transmission: Code Barcode Prefix Name Preamble Postamble Suffix Length data Insert groups...
  • Page 84 Test Chart CODABAR-PARA CODE-11 PARA CODE-128 PARA CODE-39 PARA CODE-93 PARA EAN-13 PARA...
  • Page 85 PDF-417 STANDRAD-25 PARA CODE-16K 87549 EAN-8 PARA INDUSTRIAL-25 PARA UPCE PARA...
  • Page 86 INTERLEAVED-25 PARA MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA UK/PLESSEY PARA Micro-PDF...
  • Page 87 ASCII Code Table Note: For keyboard wedge only. Null Down Left Right PgUp PgDn Home Enter Insert Ctrl+ Delete Alt+ “ & ‘ ★ < >...
  • Page 88 Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your AS-8110/8150/8210/8310, scanner over the host terminal/computer, scan the Barcode standard parameter setting list bar code. Unique parameter list If you wish to display the unique parameter setting list, scan the unique parameter list bar code System parameter setting list If you wish to display the product information and revision...
  • Page 89 Firmware version list If you wish to display the firmware version, scan the Firmware version list. WARNING: Default value initialization If you wish to return the AS-8110/8150/8210/8310 to all the factory default settings, scan the Default value initialization bar code. Exit...
  • Page 90 Finish...
  • Page 91 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.
  • Page 92 following measures: ---Reorient or relocate the receiving antenna. ---Increase the separation between the equipment and receiver. ---Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ---Consult the dealer or an experienced radio/TV technician for help.
  • Page 93 OPERATION MANUAL Interface: Please link the applicable interface cable to the PC and the Cradle POWER: plug in via the Cradle (First link the interface cable to the PC and the Cradle, then switch on the Cradle) Application: Receiving the code by using the subsidiary application pattern terminating machine (38400-N-8-1).
  • Page 94 CHARGE: Put the Scanner on the Cradle to charge. The green light is glitter while in charge. After completed charging the light will stay green. A PARAMETER : Please refer to the way of parameter settlement. Table 1: Cradle LED status Cradle Power LED Unlink The yellow light on...
  • Page 95 Table 2: Scanner LED status Scanner LED Beep Scanner not LED Off working (Sleep mode) On line The yellow light glittering Data deliver The green light One short success glittering beep Data deliver One short failed and one long beeps Scanner low The red light pressure...
  • Page 96 根據交通部低功率管理辦法規定: 第十二條 經型式認證合格之低功率射頻電機,非經許可,公 司、商號或使用者均不得擅自 變更頻率、加大功率或變更原設計之特性及功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾 合法通信;經發現有干擾現象 時,應立即停用,並改善至無干擾時方得繼續使 用。 前項合法通信,指依電信規定作業之無線電信 。低 功率射頻電機須忍受合法通信 或工業、科學及醫療用電波輻射性電機設備之干 擾。...