LOCAL AIR CONDITIONER
Model: PELL0061
1

Advertisement

Table of Contents
loading

Summary of Contents for Pro-Elec PELL0061

  • Page 1 LOCAL AIR CONDITIONER Model: PELL0061...
  • Page 2: Important Safety Information

    Please read these instructions carefully before use and retain for future reference. • Do not install and use the appliance in a bathroom or other humid environments. • Do not pull out the mains plug to turn off the appliance. IMPORTANT SAFETY INFORMATION •...
  • Page 3: Product Overview

    PRODUCT OVERVIEW POSITIONING & INSTALLATION Positioning Warning: before using the local air conditioning, keep it upright for at least two hours. • The air conditioner must stand upright on an even surface. Front • Do not position near a bath, sink or other permanently damp or wet areas. 1 Control panel •...
  • Page 4: Installation Errors

    INSTALLATION ERRORS REMOTE CONTROL To operate efficiently the air must be able to flow freely into the exhaust hose. To assist this: 1. POWER • Avoid any sharp bends or kinks in the exhaust hose. • Keep it as level as possible. 2.
  • Page 5: Water Drainage

    NOTE: Sleep mode is not available in dehumidifying and fan mode. MAINTENANCE Important: In order to avoid an electric shock, power-off the air conditioner and Compressor Protection disconnect the mains plug before performing any maintenance or repair activities. After powering on, or a restart, there is a three minute delay before the compressor starts to operate.
  • Page 6: Further Safety Information

    The following checks shall be applied to installations using flammable refrigerants: FURTHER SAFETY INFORMATION The charge size is in accordance with the room size within which the Information on servicing refrigerant containing parts are installed. • Checks to the work area prior to beginning work on systems containing flammable The ventilation machinery and outlets are operating adequately and are not refrigerants, safety checks are necessary to ensure that the risk of ignition is obstructed.
  • Page 7 Repair to intrinsically safe components to be repeated several times. Compressed air or oxygen shall not be used for this • Do not apply any permanent inductive or capacitance loads to the circuit without task. ensuring that this will not exceed the permissible voltage and current permitted for •...
  • Page 8: Troubleshooting

    Do not exceed the maximum working pressure of the cylinder, even TROUBLESHOOTING temporarily. When the cylinders have been filled correctly and the process completed, Trouble Cause Solution make sure that the cylinders and the equipment are removed from site • Power is off •...
  • Page 9: Technical Specification

    TECHNICAL SPECIFICATION Main voltage 220-240V ~ 50Hz Rated input power 1550W Power standby mode 0.51W Cooling capacity 4.1kW (14,000BTU/h) Air flow 400m³/h Sound power level 65dB (A) Refrigerant/charge R290/260g Global warming potential 0.585kgCO Energy efficiency ratio (EER) Energy efficiency class Fan speeds Thermostat 16 - 31°C...