Rev. (a)

Thor VM2WG Screen Blanking

Note:
Before this process begins, the steps outlined in Power Cable Connection need to be performed for either the
60VDC Connection
Caution:
For installation by trained service personnel only.
Caution:
For proper and safe installation, the input power lead to the Screen Blanking Box requires a 3 Amp maximum time
delay (slow blow) high interrupting rating fuse. Note: For North America, a UL Listed fuse is to be used.
When routing any additional cables for screen blanking:
Route the cable the shortest way possible removing any left-over cable
l
Fuses and cabling are user supplied. Therefore, route these cables so they are protected from physical damage and
l
from surfaces that might exceed the cable's rated temperature threshold.
Cable should be protected from physical damage from moving parts
l
Do not expose the cable to chemicals or oil that may cause the wiring insulation to deteriorate
l
Always route the cable so that it does not interfere with safe operation and maintenance of the vehicle.
l
Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot intervals,
l
taking care not to over tighten and pinch conductors or penetrate outer cable jacket.