Ignition Control Power Scheme, Ignition Off; Auto On Power Scheme - Honeywell Thor VM2CG User Manual

Vehicle-mount computer microsoft windows embedded ce 6 operating system
Table of Contents

Advertisement

Rev. (a)

Ignition Control Power Scheme, Ignition Off

This power scheme is used when the Ignition Control power configuration mode is selected and the vehicle ignition is Off.
Switch state to User Idle
Switch state to System Idle
Switch state to Suspend
Shutdown

Auto On Power Scheme

This power scheme is used when the Auto On power configuration mode is selected.
Switch state to User Idle
Switch state to System Idle
Switch state to Suspend
Shutdown
The timers are cumulative. The System Idle timer begins the countdown after the User Idle timer has expired and the Suspend
timer begins the countdown after the System Idle timer has expired. When the User Idle timer is set to "Never", the power
scheme timers never place the Thor VM2CG in User Idle, System Idle, Suspend or Shutdown modes (even when the Thor
VM2CG is idle).
Using the UPS Power Scheme Defaults listed above, the cumulative effect results in the following:
The backlight turns off after 30 seconds of no activity,
l
The display turns off after 90 seconds of no activity (1 minute + 30 seconds),
l
The Thor VM2CG enters Suspend after 11 minutes and 30 seconds of no activity,
l
And the Thor VM2CG shuts down after 31 minutes and 30 seconds of no activity.
l
2-14
Default is After 1 minute
Default is After 5 minutes
Default is After 1 hour
Default is After 8 hours
Default is After 1 minute
Default is After 1 hour
Default is After 8 hours
Default is Never