7. Slide drain pump into the ice maker base on the right side.
The pump mounting tab should slip into the rectangular slot
in the ice maker base. It will be necessary to tip the pump
slightly to slip into the slot. See "Drain Pump Mounting Tab
Slot" illustration.
Drain Pump Mounting Tab Slot
A. Mounting tab slot
Drain Pump Installed
A. Drain pump installed
8. Align the 2 screw holes at the rear of the pump. Use two
#8-32 x 3/8" screws, supplied. See "Parts Locations"
illustration.
9. Connect drain tube to ice maker bin outlet (5/8" I.D.), using
7/8" adjustable clamp, supplied. See "Drain Tube" illustration.
10. Coil ice maker power cord into a 4" (10.2 cm) diameter
coil. Wrap electrical tape around the power cord in several
places to keep the cord in a coil. Locate coiled power cord
between the drain pump and side of enclosure and plug into
the receptacle of the drain pump. See "Parts Locations"
illustration.
11. Attach the drain pump power cord to ice maker unit base with
clamp and screw (removed in Step 6) that was used to attach
ice maker power cord. See "Parts Locations" illustration.
12. Place new rear panel (small one for 15" ice makers, large one
for 18") against the back of the ice maker. Route the vent tube
and drain pump discharge tube through cutouts in the rear
panel.
13. Secure rear panel with original screws. See "Rear Panel"
illustration.
14. Secure vent tube to back of ice maker using three clamps
and three #8-32 x 3/8" screws, supplied. See "Vent Tube"
illustration.
Vent Tube
NOTE: Do not pinch, kink or damage the vent tube. Check that it
is not damaged or pinched or kinked between the cabinet and the
ice maker.
B
A
A
15. Attach 1/2" I.D. x 10 ft (3 m) drain tube to pump discharge
tube. See "Parts Locations" illustration.
NOTE: Do not connect outlet end of drain tube to a closed
pipe system to keep drain water from backing up into the ice
maker.
16. Connect ice maker to water supply and install ice maker as
specified by the product installation instructions.
17. Check all connections for leaks.
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
18. Plug in ice maker or reconnect power.
19. Turn on ice maker.
20. Wait for rinsing cycle, approximately 5 minutes, to be sure the
ice maker is operating properly.
A. Vent tube
B. Clamps and screws
WARNING
Electrical Shock Hazard