Adjusting the minimum setting for natural
or town gas
1. Light the burner and turn it to the minimum
position.
2. Extract the gas cock knob and turn the
adjustment screw next to the tap rod
(depending on the model) until the
correct minimum flame is achieved.
3. Refit the knob and verify that the burner
flame is stable.
4. Turn the knob rapidly from the maximum
to the minimum setting: The flame should
not go out.
5. Repeat the operation on all gas cocks.
Burner and nozzle characteristics tables
NG 1.0 kPA
Nominal gas consumption (MJ/h)
Injector (1/100 mm)
Primary air (mm)
ULPG 2.75 kPa
Nominal gas consumption (MJ/h)
Injector (1/100 mm)
Primary air (mm)
Installation
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
tap rod clockwise all the way.
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label on the appliance with the
one corresponding to the new gas.
The label is inserted inside the
nozzle pack (where present).
Lubricating the gas cocks
Over time the gas taps may become difficult
to turn and get blocked. Clean them
internally and replace the lubrication
grease.
Lubrication of the gas taps should
be performed by a specialised
technician.
AUX
SR
4.0
6.1
0.85
1.10
4
4
AUX
SR
4.0
6.1
0.54
0.68
10
10
RR
R
9.0
10.4
12.6
1.32
1.45
1.60
4
4
RR
R
9.0
10.4
12.6
0.80
0.85
0.93
10
10
UR
4
UR
10
23