Download Print this page

Advertisement

Quick Links

Installation Guide
for
AC-1000RF V1.0
Ness Corporation.
www.ness.com.au

Advertisement

loading
Need help?

Need help?

Do you have a question about the VIRDI AC-1000RF and is the answer not in the manual?

Questions and answers

Summary of Contents for Ness VIRDI AC-1000RF

  • Page 1 Installation Guide AC-1000RF V1.0 Ness Corporation. www.ness.com.au...
  • Page 2: External Connectors

    1. External Connectors Wiegand, RS232 & RS485 Interface DC Power Input Interface Data0 (Brown) - 1 Data1 (Red) - 2 Wiegand In Ground (Black) - 3 Data0 (Orange) - 1 Wiegand Out Data1 (Yellow) - 2 P - 3 FGND (Green) - 3 Ground (Black) - 3...
  • Page 3 2. Main board feature J120 : RS232 J102 : Wiegand Out J201 : DC Input J301 : LAN Interface SW120 : RS-485 termination F201 : Fuse resistor ON/OFF J121 : RS-485 Interface J101 : Wiegand In J151 : Lock Interface SW101: RS232 (TTL/232 level select) Lock Type Select S/W Volume...
  • Page 4 3. Schematic for Door Lock Interface SW151 DJMM-12V Strike/MT LM_COM1 LM_COM1 Auto Door SW153 K151 DJMM-12V G6S-2-5VDC LM_NC Door_Lock1 LM_NO LM_NO LM_NO LM_NO Motor PV152 VN20-260LJ D151 DC156 SW152 DJMM-12V 104C2 PV151 D152 Strike VN20-260L-751JT R165 102R LockCon1 LockCon1 LockCon1 LockCon1 LockCon1 LockCon1...
  • Page 5 4. Connecting Dead-Bolt Type Door Lock ( Fail Safe ) 4. 1. Connect with one system & one lock ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 (-)Black Strike SW153 SW152 (+)Red - C + NO/Motor Motor 1 2 3 4 5 6 Strike/MT Strike/MT 1 2 3 4...
  • Page 6 4. Connecting Dead-Bolt Type Door Lock ( Fail Safe ) 4. 2. Connect with two system & one lock ◈ Lock Type Select Switch (-)Black System 1 System 2 (+)Red 1) SW2 2) SW151~SW154 1) SW2 2) SW151~SW154 - C + Strike Strike 1 2 3 4...
  • Page 7 5. Connecting Strike Type Door Lock ( Fail Safe ) 5. 1. Connect with one system & one lock ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 Strike (-)Black SW153 SW152 (+)Red NO/Motor Motor 1 2 3 4 5 6 Strike/MT Strike/MT SW154...
  • Page 8 5. Connecting Strike Type Door Lock ( Fail Safe ) 5. 2. Connect with two system & one lock ◈ Lock Type Select Switch System 1 System 2 1) SW2 2) SW151~SW154 1) SW2 2) SW151~SW154 Strike Strike SW153 SW152 SW153 SW152 NO/Motor...
  • Page 9 6. Connecting Strike Type Door Lock ( Fail Secure ) 6. 1. Connect with one system & one lock ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 Strike (-)Black SW153 SW152 (+)Red NO/Motor Motor 1 2 3 4 5 6 Strike/MT Strike/MT SW154...
  • Page 10 6. Connecting Strike Type Door Lock ( Fail Secure ) 6. 2. Connect with two system & one lock ◈ Lock Type Select Switch System 1 System 2 1) SW2 2) SW151~SW154 1) SW2 2) SW151~SW154 Strike Strike SW153 SW152 SW153 SW152 NO/Motor...
  • Page 11 7. Connecting EM Type Door Lock ( Fail Safe ) 7. 1. Connect with one system & one lock ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 Strike SW153 SW152 NO/Motor Motor Brown (+) Door Monitor 1 2 3 4 5 6 Strike/MT Strike/MT SW154...
  • Page 12 7. Connecting EM Type Door Lock ( Fail Safe ) 7. 2. Connect with one system & two lock ** Use external DC Power Adapter ◈ Lock Type Select Switch Lock 1 1) SW2 2) SW151~SW154 Strike SW153 SW152 NO/Motor Motor 1 2 3 4 5 6 Strike/MT...
  • Page 13 8. Connecting Auto Door ( Contact Control ) 8. 1. Connect with two system & one door ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 Auto Door Motor Auto Door Operating Part Strike SW153 SW152 NO/Motor Motor Auto-Door Sensor Auto-Door Monitor 1 2 3 4 5 6 Strike/MT...
  • Page 14 8. Connecting Auto Door ( Contact Control ) 8. 2. Connect with two system & one door ◈ Lock Type Select Switch System 1 System 2 1) SW2 2) SW151~SW154 1) SW2 2) SW151~SW154 Strike Strike SW153 SW152 SW153 SW152 NO/Motor Motor NO/Motor...
  • Page 15 9. Connecting Motor Lock ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 Strike SW153 SW152 NO/Motor Motor 1 2 3 4 5 6 Strike/MT Strike/MT SW154 SW151 AutoDoor AutoDoor ◈ Wiring diagram Lock(+) Pin 1 Door Lock1 (Brown) - 1 Lock(-) Pin 2 Door Lock2...
  • Page 16 10. Connecting 2 Emergency Lamps ◈ Lock Type Select Switch Emergency Emergency Lamp 2 Lamp 1 1) SW2 2) SW151~SW154 Strike SW153 SW152 NO/Motor Motor 1 2 3 4 5 6 Strike/MT Strike/MT SW154 SW151 AutoDoor AutoDoor Ground (-) Ground (-) 12 V (+) 12 V (+) ◈...

This manual is also suitable for:

Virdi ac-1000saVirdi ac-1000