II. Installation and Operating Instructions
• The appliance must be installed in accordance with applicable national, state, and
local codes and regulations.
• Failure to install, operate, and maintain the appliance in accordance with this
manual will adversely affect safety, performance, component life, and warranty
coverage and may result in costly water damage.
• CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews
are securely in place after installation. Make sure that none have fallen into the
storage bin.
A. Location
• The appliance is not intended for outdoor use. Normal operating ambient
temperature must be within 45°F to 100°F (7°C to 38°C). If the normal operating
ambient temperature is above 90°F (32°C), the compressor insulation cover
must be removed. Normal operating water temperature must be within 45°F to
90°F (7°C to 32°C). Operation of the appliance, for extended periods, outside of
these normal temperature ranges may affect appliance performance.
• The appliance will not work at sub-freezing temperatures. To prevent damage
to the water supply line, drain the appliance if the air temperature is going to go
below 32°F (0°C). See "IV. Preparing the Appliance for Periods of Non-Use."
• The appliance should not be located next to ovens, grills, or other high heat producing
equipment.
• On air-cooled model, allow at least 12" (30 cm) clearance on the left side and 6" (15 cm)
clearance at rear, right side, and top for proper air circulation and ease of maintenance
and/or service should they be required. On water-cooled model, allow 6" (15 cm)
clearance at rear, sides, and top.
• The location should provide a firm and level foundation for the appliance.