Water Supply And Drain Connections - Hoshizaki DKM500BAH Instruction Manual

Crescent cube icemaker / dispenser
Hide thumbs Also See for DKM500BAH:
Table of Contents

Advertisement

F. Water Supply and Drain Connections
See Figs. 3 through 5
Water supply and drain connections must be installed in accordance with applicable
national, state, and local regulations.
• Normal operating water temperature must be within 45°F to 90°F (7°C to
32°C). Operation of the appliance, for extended periods, outside of this normal
temperature range may affect appliance performance.
• Water supply pressure must be a minimum of 10 PSIG and a maximum of
113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve
is required.
• External filters, strainers, or softeners may be required depending on water quality.
Contact your local Hoshizaki Certified Service Representative or local Hoshizaki
distributor for recommendations.
• In areas where water damage is a concern, install in a contained area with a floor
drain.
• A plumbing permit and services of a licensed plumber may be required in some areas.
• The icemaker drain line, storage bin drain line, and water-cooled condenser drain line (if
applicable) must be run separately.
• Drain lines must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get a good
flow. A vented tee connection is also required for proper flow.
• Drain lines should not be piped directly to the sewer system. An air gap of a minimum of
2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker,
storage bin, and water-cooled condenser (if applicable) and the floor drain.
WARNING
NOTICE
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dkm500bwh

Table of Contents