Wiring
<Using NPN output>
Gray cable
Gray cable
(with black line)
Interlock function
External device monitor function Invalid
Auxiliary output 1
*Symbols
Switch S1
● Test / Reset input
0 to +2.5V (source current 5mA or less): Emission, Open: Emission halt
Switch S2
● Muting input A / B, Override input
0 to +2.5V (source current 5mA or less): Valid, Open: Invalid
K1, K2: Safety relay unit, etc.
74
(Gray) Application indicator input 1
(Gray / Black) Application indicator input 2
(Pale purple) Interlock setting input
(Brown) +V
(Red / White) Muting auxiliary output
(Pale blue) Output polarity setting / Lockout release input
(Yellow) Override input
(Pink) Test / Reset input
(Blue) 0V
(Red) Auxiliary output 1
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Pale purple) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting / Lockout release input
(Pink) Muting input A
(Yellow) Muting input B
(Blue) 0V
(Red) Auxiliary output 2
(Gray) NC
Invalid (auto reset)
Not possible
*S1
© Panasonic Industrial Devices SUNX Co., Ltd. 2020
+
24V DC
+20
%
-30
*S2
K1
K2
*S2
*S2