Lenovo ThinkSystem SR650 V2 Reference page 104

Hide thumbs Also See for ThinkSystem SR650 V2:
Table of Contents

Advertisement

This message is for the use case when an implementation has detected that an Array Rebuild is in
Progress.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0178
User Action:
Information only; no action is required.
• FQXSPSD0008L: Array failed on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]).
This message is for the use case when an implementation has detected that an Array Failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0176
User Action:
Collect RAID log and service data log from the XCC WebGUI, and contact Lenovo Support.
• FQXSPSD2000I: The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Drive has been Removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0163
User Action:
Complete the following steps until the problem is solved:
1. If the drive was intentionally removed, make sure that there is a filler in the drive bay.
2. If the drive was not removed, make sure that the drive is correctly seated.
3. If the drive is correctly seated, replace the drive, collect service data log from the XCC WebGUI, and
contact Lenovo Support.
• FQXSPSD2001I: The [StorageVolumeElementName] has recovered from a fault.
This message is for the use case when an implementation has detected a Drive was Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0167
User Action:
100
ThinkSystem SR650 V2 Messages and Codes Reference