Download Print this page
GE Monogram ZDBC240NBS Dimensions And Specifications
GE Monogram ZDBC240NBS Dimensions And Specifications

GE Monogram ZDBC240NBS Dimensions And Specifications

Stainless steel beverage center

Advertisement

Quick Links

ZDBC240NBS – GE Monogram Stainless Steel Beverage Center
Dimensions and Specifications (in inches)
Installation Space
The Monogram
Beverage Center may be installed beneath a
®
countertop or can be used free-standing.
• If installing between frameless cabinets, a 1/2"-wide filler strip
or side panel may be required. The filler strip will act as a spacer
between the door case and adjacent cabinet and will prevent
interference with cabinet door swing. The width of the opening
must include filler panels.
Note: When installed, the door should project forward 1" of
adjacent 24"-deep cabinets.
Locate Outlet
10-1/2"
9"
Max.
34-1/2"-35"
1-1/2"
23-3/4" Min.
25-1/2"
Including
Handle
Location Requirements
All Monogram Refrigeration Modules may be closed in on the top
and sides as long as the front is unobstructed for air circulation and
door swing.
• Do not install these products where the temperatures will go
below 55°F (13°C) or above 90°F (32°C).
• Do not install where they will be subject to direct sunlight,
heat or moisture.
• These products are not designed to be stacked one over the other.
Specification Revised 4/06
120022
24" Min.
23-3/4"
34-1/4"
to
34-3/4"
23-3/4"
Side-by-Side Installation
For a complete refreshment center, install a Monogram Wine Reserve
and Beverage Center together.
• Products must operate from separate properly grounded
receptacles.
Door Swing Clearances
All Monogram Refrigeration Modules are factory set for a 110°
door swing.
When installed in a corner:
• Allow the minimum door swing clearances shown.
• The minimum clearance shown at 90° will allow full extension
of drawers and shelves.
10"
A
Minimum to Wall
Minimum to Wall
110° Door
Swing
110°
Electrical
A 120V, 60Hz, 15 or 20 amp power supply is required. An individual
properly grounded branch circuit or circuit breaker is recommended.
Install a properly grounded 3-prong electrical recessed into the
back wall as shown. Electrical must be located on rear wall as shown.
Note: GFCI (ground fault circuit interrupter) is not recommended.
Listed by
Underwriters
Laboratories
For answers to your Monogram,
GE
appliance questions, visit our website at
®
GEAppliances.com or call GE Answer Center
service, 800.626.2000.
90° Door
21-5/8"
Swing
23-5/8"
90°
B
4"
Minimum to Wall
Minimum to Wall
GE Profile
or
®
®

Advertisement

loading

Summary of Contents for GE Monogram ZDBC240NBS

  • Page 1 ZDBC240NBS – GE Monogram Stainless Steel Beverage Center Dimensions and Specifications (in inches) Installation Space The Monogram Beverage Center may be installed beneath a ® countertop or can be used free-standing. • If installing between frameless cabinets, a 1/2"-wide filler strip or side panel may be required.
  • Page 2 ZDBC240NBS – GE Monogram Stainless Steel Beverage Center ZDBC240NBS ZDBR240PBS Specification Revised 4/06 120022 Features and Benefits • Adjustable manual thermostat – Maintains the ideal temperature for aging or serving wine • Removable spillproof glass shelves – Helps contain spills for ease of cleaning •...