Hardware installation
5.6

Notes on connecting/disconnecting cables

V
CAUTION!
Always read the documentation supplied with the device you wish to
connect.
Never connect, or disconnect cables during a thunderstorm.
Never pull on a cable when disconnecting it. Always take hold of the
cable by the plug.
Follow the sequence described below to connect or disconnect external
devices to or from the server:
Be sure to wait for 10 seconds or more after shutdown before turning the
server on.
Connecting cables
Ê Turn off all power and equipment switches.
Ê Disconnect all power plugs from the properly grounded power outlets.
Ê Connect all cables to the server and peripherals.
Ê Plug all data communication cables into the utility sockets.
Ê Plug all power cords into the properly grounded power outlets.
Disconnecting cables
Ê Turn off all power and equipment switches.
Ê Disconnect all power plugs from the properly grounded power outlets.
Ê Unplug all data communication cables from the utility sockets.
Ê Disconnect the relevant cables from the server and all the peripherals.
I
For connecting or disconnecting LAN cables, the server does not need
to be powered off. To avoid loss of data teaming function has to be
enabled.
Information for ensuring electromagnetic compatibility
All data and signal cables must have sufficient shielding. The use of cable type
S/FTP Cat5 or higher is recommended.
Use of unshielded or badly shielded cables may lead to increased emission of
interference and/or reduced fault-tolerance of the device.