Page 1
OWNER’S MANUAL PORTABLE GENERATOR MODEL NUMBER P05703 Rev Level:01 IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Ensure engine is stopped and level before performing any maintenance or service. Record product information to reference when ordering parts or obtaining warranty coverage.
Save these original instructions for future reference. This manual covers operation and maintenance of the FIRMAN generators. All information in this publication is based on the latest production information available at the time of approval for printing.
SAFETY PRECAUTIONS • WARNING POISONOUS GAS HAZARD. • • • • English Page 02 Customer Service: 1-844-FIRMAN1...
Page 5
CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces. INCORRECT USAGE Do not operate in any of the following locations: Near any door, window or vent Garage Basement...
Page 6
WHEN OPERATING EQUIPMENT WARNING • • DO NOT tip engine or equipment at angle which causes fuel to spill. • DO NOT stop engine by moving choke • control to “Start” position. WHEN TRANSPORTING, MOVING • OR REPAIRING EQUIPMENT • NEVER start or stop engine with electrical Transport/move/repair with fuel tank devices plugged in and turned on.
Page 7
• When using generator for backup power, WARNING notify utility company. Unintentional sparking • Use a ground fault circuit interrupter (GFCI) could cause fire or in any damp or highly conductive area, electric shock resulting such as metal decking or steel work. in death or serious •...
ASSEMBLY Install the Handle The generator requires some assembly prior to 1. Place the handle K over the mounting channel usage. If problems arise when assembling the on the frame. generator, call 1-844-347-6261. 2. Secure the handle to the frame using the two Install the Wheel Kit handle flange bolts H(M8x50).
Battery Cable Connection NOTE: The generator comes equiped with the positive(red) and negative(black) cables already attached to battery terminals. 1. Cut wire tie that is binding the black battery cables A and B. 2. Insert the male connector of cable A into female connector of cable B. English Page 08 Customer Service: 1-844-FIRMAN1...
12- Control Panel 5- Fuel Valve 13- Handle 6- Air Filter 14- Battery 7- 389cc FIRMAN OHV Engine 15- Remote Holder 8- Recoil Starter The remote controller can be placed inside the remote holder for easy access. *We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on this page.
Control Panel NOTE: Total power drawn from all receptacles must not exceed the name plate rating. Engine Start Switch – Used to start engine 120/240V, 30A Twist-Lock – (NEMA L14-30R) from the starter motor(Electric start model Maximum full load current may be drawn from this 120/240 Volt, 30 Amp receptacle.
Remote Start 2. Flip the battery switch to the "ON"(l) position. This generator is equipped with a wireless remote start system for starting and stopping. The Remote Start functions are enabled when: 1.The Engine Switch is in the “RUN”(l) position, AND 2.The Battery Switch is in the “ON”(l) position.
SPECIFICATIONS Model P05703 Starting Watts 7125 5700 Running Watts Rated AC Voltage 120/240V Rated Fequency 60Hz Phase Single Voltage Regulator Power Factor Standard Total Harmonic Distortion(THD) Alternator Type Brushed Engine FIRMAN Engine Type Single Cylinder, 4-Stroke OHV Air Cooled Displacement...
4.Using oil funnel, slowly pour contents of ADD ENGINE OIL provided oil bottle into oil fill opening to the "H" mark on dipstick. Be careful do not CAUTION overfill. Overfilling with oil could cause the engine to not start or hard starting. NOTE: Degrees Celsiusº(Outside) 5.Replace oil fill cap/dipstick and fully tighten.
ADD FUEL Fuel must meet these requirements: • Clean, fresh, unleaded gasoline. • Use regular UNLEADED gasoline with the generator engine with a minimum 87 octane / 87 AKI (91 RON). For high altitude use, see "Operation at High Altitude". •...
THE GENERATOR (STATOR WINDING) AND THE Installation instructions are also available in the FRAME. Technical Bulletin area of the FIRMAN internet site. The part number and recommended minimum Connecting to a Building's Electrical System altitude for the application of the high altitude carburetor main jet is listed in the table below.
5. OPERATION • Generator Location WARNING Make sure you review each warning in order to • prevent fire hazard. Keep area clear of inflammables or other hazardous materials. Select a site that is dry, well ventilated and protected from the weather. •...
Starting the Generator (Recoil Start) 7. Move the choke lever to the “START” position. 1. Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment. 2. Check oil level and fuel. 8.
4. Turn the fuel valve to the “ON” (l)position. Starting the Generator (Electric Start) Electric Start and Remote Start Operations 5. Flip the engine switch to the "RUN"(l) position. WARNING 6. Flip the battery switch to the "ON"(l) position. WARNING 7.
9. Do not over-choke. As soon as engine starts and warms up, move the choke lever to the “RUN” position. 4. Turn the fuel valve to the “ON” (l)position. 10. Allow generator to run at no load for few minutes upon each initial start-up to permit engine and generator to stablize.
If the engine fails to start within 3 to 5 seconds, the engine will attempt to start five additional times. If the generator failed to start, the remote start indicator light will flash. If the generator fails to start after a total of six attempts, the start button on the remote control must be pushed again to begin another cycle of six start attempts.
1.DO NOT try to restart the engine. 4. Flip the battery switch on "OFF"(O) position. 2.Contact an Authorized FIRMAN Service Dealer. 3.DO NOT operate engine until oil level is corrected. If oil level is below LOW mark on dipstick: 1.Add oil to bring level to HIGH mark.
• Use fresh and high quality lubricating oil to the ENGINE MAINTENANCE specified quantity. If contaminated or deteriorated oil is used or To prevent accidental starting, remove and the quantity of the engine oil is not sufficient, ground spark plug wire before performing any the engine damage will result and its life will be service.
Spark Plug Maintenance Cleaning Fuel Strainer Changing the spark plug will help your engine Dirt and water in the fuel are removed by the fuel to start easier and run better. strainer. (a) Remove the spark plug cap. (b) Remove spark plug using provided wrench. (a) Remove the strainer cup and throw away water and dirt.
• DO NOT touch hot parts and AVOID hot exhaust CAUTION gases. • Failure to clean the spark arrester will result in Allow equipment to cool before touching. degraded engine performance. • Keep at least 5 feet (1.5 m) of clearance on all GENERATOR MAINTENANCE sides of generator including overhead.
WARNING Long Term Storage It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor, fuel hoses or tank during storage. Also, experience indicates that alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads To avoid electric shock: to separation and formation of acids during storage.
Page 29
8-Keep the engine switch and fuel valve on “OFF” position. 9-Cover the unit and store in a clean, dry place out of direct sunlight. NEVER USE WATER TO CLEAN GENERATOR. NOTE: • We recommend always using a fuel stabilizer. A FUEL STABLIZER will minimize the formula- tion of fuel gum deposits during storage, the fuel stabilizer can be added to the gasoline in the fuel tank, or into the gasoline in a storage...
TROUBLE SHOOTING Problem Cause Correction 1. Circuit breaker is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no 3. Poor connection or defective cord 3. Check and repair. AC output is available. set.
P05703 PARTS LIST Description Qty. Description Qty. NO. Part Number NO. Part Number FIRMAN 389cc Engine 357713532 Isolator B 357713560 Isolator A 357713501 Rubber Cap B 357713533 Wheel 336713528 Flange. Bolt M6×8 357713534 Axle Assy 357713502 357713535 Generator Wind Shield...
Page 34
FIRMAN 389cc Engine Parts List Qty. Qty. NO. Part Number NO. Part Number Description Description Crankcase Subassembly. Spring 357723500 336723601 Bolt, Drain Plug Step Moter Holder 357723501 357723553 Washer,Drain Bolt Step Moter 357723502 336723603 Sensor, Engine Oil Bolt M4×8 357723503 336723604 Flange Bolt M6×15...
1. Model No. ,Rev. Level and Serial No. and all of Purchase specifications shown on the Model No./Serial Contact the FIRMAN Service Center and FIRMAN No. plate. will troubleshoot any issue via phone or e-mail. 2. Parts number or numbers as shown in the If the problem is not corrected by this method, Parts List section.
Page 36
Peoria, AZ 85381 Normal maintenance is not covered by this www.firmanpowerequipment.com warranty. We are FIRMAN POWER - And we are here for you. Other Exclusions Customer Service Desk - 1-844-347-6261(1-844-FIRMAN1) This warranty excludes: 6am PST(9am EST) until 8pm EST(5pm PST) –...
Page 37
If any such part fails during the period of warranty coverage, the part will be repaired or replaced by FIRMAN at no charge to the owner. Any such part repaired or replaced under the warranty will be warranted for the remaining warranty period.
Page 38
(8) Throughout the emissions warranty period defined in Subsection (b)(2), FIRMAN will maintain a supply of warranted parts sufficient to meet the expected demand for such parts. (9) Any replacement part may be used in the performance of any warranty maintenance or repairs and must be provided without charge to the owner.
Page 39
Firman Power Equipment Inc. 8716 West Ludlow Dr. Suite #6 Peoria, AZ 85381 www.firmanpowerequipment.com P/N:357745452 Rev 0 5...
Page 40
Panneau de Contrôle NOTE: Puissance totale tirée de tous les récipients ne doit pas dépasser la valeur nominale de la plaque signalétique. Interrupteur du Moteur – Utilisé pour démarrer le 120V, 30A Twist-Lock (NEMA L5-30R) moteur à partir du moteur de démarreur (Démarreur Pleine charge maximale de 30 Ampères de courant électrique modèle uniquement).
Page 41
2. L'interrupteur de la batterie à la position "ON" (l). Démarreur à Distance Ce générateur est équipé d'une télécommande sans fil le démarrage du système pour démarrer et arrêter. Les fonctions de démarrage à distance sont activés lorsque: 1.Le commutateur du moteur est en position "RUN" (l), ET 2.Le commutateur de batterie est en position "ON"...
Page 42
à La carcasse du moteur UN MESSAGE IMPORTANT SUR LA TEMPÉRATURE Votre produit Firman Power Equipment est dessiné et évalué pour une opération continue aux températures ambiantes jusqu'à 40 ° C (104 ° F). Lorsque votre produit a besoin, votre produit peut être opéré...
Page 43
4.Utilisez l'entonnoir d'huile, versez lentement le AJOUTEZ L'HUILE DE MOTEUR contenu de la bouteille d'huile fournie en remplissage d'huile ouverture à la marque '' H1 'sur la jauge. CAUTION Soyez prudent de ne pas trop remplir. Un remplissage NE PAS tentez de démarrer le moteur avant qu'il excessif d'huile peut causer le moteur à...
Page 44
Ajoutez le Combustible Le combustible doit répondre aux exigences: • Propre, frais, l'ssence sans plomb. • Utilisez l'ssence sans plomb rulieavec le moteur du gateur du minimum 87 octane 87 AKI (91 RON) Pour utiliser l'altitude haute, voyez 'opération sur l'altitude haute' . •...
Page 45
électrique d'un bâtiment doivent être d'installation sont également disponibles dans la effectuées par un électricien qualifié. La connexion zone Bulletin technique sur le site internet FIRMAN. doit isoler la puissance du générateur de secteur Le numéro du part et l'altitude minimale recommandée d'alimentation ou d'autres sources d'énergie...
Page 46
• Opérez cet appareil uniquement à l'extérieur OPÉRATION loin des fenêtres, portes et ventilations à réduire Location de Générateur le risque de monoxyde de carbone en provenant de l'accumulation et potentiellement d'être attiré AVERTISSEMENT vers les espaces occupés. • Assurez-vous vérifier chaque avertissement afin de Installez des alarmes de monoxyde de carbone provenir le danger d'incendie.
Page 47
7. Placez le levier de starter en position "START". Démarrer le Générateur (Recoil Démarrer) 1. Avant de démarrer le générateur, vérifiez s'il y a des pièces manquantes ou lâches et de tout dommage qui peut avoir lieu pendant le transport. 2.
Page 48
4. Tournez la valve de combustible en position «ON»(l). Si le moteur démarre après 3 essais, mais ne parvient pas à exécuter, ou si l'appareil éteint pendant l'opération, assurez-vous que l'unité est sur une surface du niveau et vérifiez le niveau d'huile propre dans le carter de moteur. Cet appareil peut être équipé...
Page 49
9. Ne pas trop étranglez. Dès que le moteur démarre et se réchauffe, déplacez le levier de l'étrangleur en position «RUN». 4. Tournez la valve de combustible en position «ON»(l). 10. Laissez le générateur fonctionner sans charge pendant cinq minutes sur chaque démarrage initial pour permettre le moteur et le générateur à...
Page 50
Si le moteur ne démarre pas à moins de 3 à 5 secondes, le moteur tente de démarrer cinq autres fois. Si le Connectez un générateur aux lignes d'alimentation générateur n'a pas pu démarrer, la télécommande de votre entreprise électrique d'utilité ou à une commencer voyant clignote.
Page 51
2.Redémarrez le moteur et si le moteur s'arrête encore, la condition de l'huile basse peut encore exister. Ne pas essayez de redémarrer le moteur. 3.Contactez un concessionnaire du service de FIRMAN L'interrupteur de batterie doit toujours être en autorisé. "OFF" (O) POSITION À LA FIN DE L'UTILISATION 4.Ne pas opérez le moteur jusqu'à...
Page 52
L'ENTRETIEN ET LA CONSERVATION LE CALENDRI Tous les Initial 25 Toutes les Toutes les Toutes les ARTICLE NOTE jours heures 50 heures 100 heures 250 heures Condition d'inspecter. Ajustez l'écart √ Bougie et néttoyez. Remplacez si necessaire. √ Inspectez le niveau d'huile. Huile de Moteur √...
Page 53
• ENTRETIEN DU MOTEUR Utilisez l'huile lubrifiante frais avec la bonne qualité à la quantité spécifiée. Pour empêcher un démarrage accidentel, retirez Si l'huile contaminée ou détériorée est utilisé ou le fil de contact de la bougie avant d'effectuer la quantité de l'huile de moteur ne suffit pas, les tout service.
Page 54
L'ENTRETIEN DE BOUGIE NETTOYAGE DU FILTRE DE CARBURANT Changeant de la bougie aidera votre moteur de La saleté et l'eau dans le carburant sont éliminés démarrer plus facilement et de mieux fonctionner. par le filtre de carburant. (a) Retirez le capuchon de bougie. (b) Retirez la bougie à...
Page 55
• NE PAS toucher les pièces chaudes et évitez CAUTION d'échappement de gaz chauds. • • Le nettoyage échoué de pare-étincelles s'entraîne Laissez l'équipement refroidir avant de le toucher. une dégradation de la performance du moteur. Gardez au moins 5 pieds (1,5 m) de dégagement L'ENTRETIEN DU GÉNÉRATEUR de tous les côtés de générateur, y compris le haut.
Page 56
STOCKAGE À LONG TERME AVERTISSEMENT Il est important de prévenir la formation de dépôts de gomme dans les parties essentielles du système d'alimentation comme le carburateur, les flexibles de carburant ou le réservoir pendant le stockage. En outre, l'expérience indique que les carburants mélangés à Pour éviter un choc électrique: l'alcool (appelés gasohol, éthanol ou méthanol) peuvent TOUJOURS brancher le câble positif (+) de la batterie...
Page 57
pour lubrifier le cylindre. Rebranchez la bougie. Tirer lentement le recul jusqu'à ce que la résistance soit ressentie. Cela ferme les vannes afin que l'humidité ne puisse pas entrer dans le cylindre du moteur. Relâcher doucement le démarreur de recul. 8-Garder l'interrupteur du moteur et la soupape de carburant sur "OFF"...
Page 58
LE DÉPANNAGE Problème Cause Correction 1. Disjoncteur est ouvert. 1. Réenclenchez le disjoncteur. Le moteur marche, mais 2. Défaut dans le générateur. 2. Contactez le dispositif de service autorisé. pas de sortie de CA est 3. Pauvre connexion ou rallonge 3.
Page 59
LE SCHEMA DES PIECES ET LA LISTE DE PIECES P05703 LE SCHEMA DES PIECES Français Service Clients: 1-844-FIRMAN1...
Page 60
389cc Moteur Schéma Des Pièces Français Service Clients: 1-844-FIRMAN1...
Page 61
P05703 LISTE DES PIECES Description Qty. Description Qty. NO. Part Number NO. Part Number FIRMAN 389cc Moteur 357713532 Isolator B 357713560 Isolator A 357713501 Moteur Bouchon Couvercle Avant B 357713533 Boulons De Bride Hexagon M6 × 8 Roue 336713528 357713534...
Page 62
389cc Liste des Pièces de Moteur Qty. Qty. NO. Part Number NO. Part Number Description Description Crankcase Subassembly. Printemps 357723500 336723601 Bolt, Bouchon De Vidange Étape Holder Moter 357723501 357723553 Laveuse, Drain Bolt étape Moter 357723502 336723603 Capteur, Huile Moteur Boulon M4 ×...
Page 63
Garantie de Réparation / Remplacement de commander les pièces de Garantie de Firman à l'acheteur original que les composants mécaniques et électriques seront remplacement et les accessoires exempts de défauts de matériaux et de fabrication pour une période d'un (1) an (pièces et main-...
Page 64
L'entretien normal n'est compris pas par cette Peoria, AZ 85381 garantie. www.firmanpowerequipment.com Les Autres Exclusions Nous sommes PUISSANCE FIRMAN - Et nous sommes Cette garantie exclut: là pour vous. – Défauts cosmétiques comme la peinture, les Service Clientèle- 1-844-347-6261(1-844-FIRMAN1) autocollants, etc.
Page 65
LA COUVERTURE DE LA GARANTIE D'ÉMISSIONS GENERALES La période de garantie commence à la date où le moteur ou l'équipement est livré à un acheteur ultime. FIRMAN garantit à l'acheteur final et à chaque acheteur suivant que le moteur est: Conçu, construit et équipé...
Page 66
(a) Les dommages indirects tels que la perte de temps, désagrément, perte d'usage du moteur ou de l'équipement, etc. (b) Des frais de diagnostic et de contrôle qui ne causent pas d'un service de garantie éligible effectué. FIRMAN POWER EQUIPMENT INC. Email: support@firmanpowerequipment.com www.firmanpowerequipment.com...
Page 67
Firman Power Equipment Inc. 8716 West Ludlow Dr. Suite #6 Peoria, AZ 85381 www.firmanpowerequipment.com Tous droits réservés. Toute réimpression ou utilisation non autorisée sans la permission écrite est strictement interdite P/N:357745452 Rev 0 5...