Door Alarm

When the door is opened for more than 1 minute, sound and light occur indicating the door is open as shown in the table below.
No Door Alarm is installed in the Upper Freezer.
Duration when door is open
Alarm sound
※ When the door is left open for one minute or more, the indicator lamp blinks and the characters on the Control Panel is illuminated.
※ From 30 seconds onwards with the door opened, the Door Alarm sounds only when the energy saving mode is set.
※ When the indicator lamp on the display area blinks due to the Door Alarm function, the Control Panel will not be activated by touching it.

Door Alarm and volume adjustment of the operation sound

You can set the sound level of the alarm louder or no alarm sound.
1
Press down
3 seconds or more until the
preset sound is heard.
The volume level is changed from " Standard " to " Louder " or " Sound off " .
Repeat the change of settings to set the operation sound you like (see the table
shown below). The sound is set to " Standard " before shipping.
Volume level
Standard
Preset sound
(Factory setting)

Set the condensation prevention heater to MIN.

Setting the condensation prevention heater to MIN saves energy.
When dew is formed in the swing partition or the partitioning iron plates, set it to the standard.
The temperature settings for the swing partition and the partitioning iron plates can be adjusted by four levels
(1 to 4), and level 4 is the most energy saving.
MIN setting of the heater
Preset sound
(Factory setting)
Setting the swing partition
1
Open the door of the Lower Freezer Compartment.
2
Press down
button 3 seconds or
more until the preset
sound is heard.
Settings of condensation prevention heater will be changed.
Repeat the change of settings to set the operation sound you
like (See the table shown above).
3
Close the door of the Lower Freezer Compartment.
Notice
● The setting will be returned to the standard when the power plug is disconnected and connected or power failure recovery takes place.
1 minute
Long beep (3 beeps)
button for
Louder
Sound off
2 long beeps
Long beep
Standard
MIN setting level 1 MIN setting level 2 MIN setting level 3 MIN setting level 4
Long beep
Push it
2 minutes
Long beep (5 beeps)
Notice
● It is impossible to adjust the volume level of
either door alarm or operation sound only.
Push it
● When the Door Alarm is disabled, characters
on the Control Panel no longer blink.
● Even if the volume level is set to " Sound off " ,
the alarm of the Ice Maker Cleaning and the
operation sound when the AUTO DOOR of
Standard
the Refrigerator Compartment and the AUTO
DOOR are set to " ON " will sound.
2 beeps
● When connecting/disconnecting the power
plug or after recovering from electric power
failure, it will return to the standard setting
where the Door Alarm sounds.
(Swing partition/Partitioning iron plates)
Long beep (2 beeps) Long beep (3 beeps) Long beep (4 beeps)
Setting the partition plate
1
Open the door of the Lower Freezer Compartment.
2
Press down
button 3 seconds or
more until the preset
sound is heard.
Settings of condensation prevention heater will be changed.
Repeat the change of settings to set the operation sound you
like (See the table shown above).
3
Close the door of the Lower Freezer Compartment.
3 minutes
Long beep (continuously), Louder
Swing partition
Partitioning iron plates
Standard
2 beeps
Push it
55