Locking The Control Panel; Door Alarm; Door Alarm And Volume Adjustment Of The Operation Sound - Hitachi R-F5700S How To Use Manual

Table of Contents

Advertisement

Locking the Control Panel

Disenabling operations can prevent erroneous operations or misuse by children.
When this indicator lamp
not be activated by touching it.
Touch
1
on the indicator lamp.
All indicator lamps turn on, and then the current settings are displayed.
2
Press down
until the preset sound is heard.
Lock of the Control Panel is changed to " On " or " Off " .
It is set to [
] " Off " before shipping.
Setting of the Control Panel's lock
"
indicator lamp "
Preset sound

Door Alarm

If any of the doors opens for one minute or more, a sound is raised to indicate that the door is open. The Display
Section blinks and the Operation Section is lit.
No Door Alarm is installed in the Upper Freezer.
Duration when door is open
Alarm sound
Display area
For operation
● Door alarm is also raised when a door is left open for 30 seconds or more in the energy saving mode. The Display Section starts to blink after one
minute from the opening.
● When the indicator lamp on the display area blinks due to the Door Alarm function, the Control Panel will not be activated by touching it.

Door Alarm and volume adjustment of the operation sound

You can set the sound level of the alarm louder or no alarm sound.
Touch
1
on the indicator lamp.
All indicator lamps turn on, and then the current settings are displayed.
2
Press down
until the preset sound is heard.
The volume level of the operation sound is changed from " Standard " to " Louder "
or " Sound off " . Repeat the change of settings to set the operation sound you like
(see the table shown below). The sound is set to " Standard " before shipping.
Volume level
Standard
Preset sound
(Factory setting)
BB0048919X_R-F5700SH_A.indd 57
(Lock of the Control Panel) is illuminated, any other portion of the Control Panel will
button on the Control Panel to turn
button for 3 seconds or more
" On "
(locked)
On
Long beep
1 minute
Long beep (3 beeps)
Blinking
Light ON
button on the Control Panel to turn
button for 3 seconds or more
Louder
Sound off
2 long beeps
Long beep
Notice
● When connecting/disconnecting the power
plug or after recovering from electric power
failure, lock of the panel for operation may
be released.
" Off "
(unlocked)
Off
2 beeps
2 minutes
Long beep (5 beeps)
Blinking
Light ON
Notice
● It is impossible to adjust the volume level of
either door alarm or operation sound only.
● When the Door Alarm is disabled, characters
on the Control Panel no longer blink.
● Even if the volume level is set to " Sound off " ,
the alarm of the Ice Maker Cleaning are set to
" ON " will sound.
● When connecting/disconnecting the power
plug or after recovering from electric power
failure, it will return to the standard setting
where the Door Alarm sounds.
Standard
2 beeps
From 3 minutes onward
Long beep (continuously), Louder
Blinking
Light ON
57