3.Status Enable register
The Status Enable Register is set by the user to enable SRQs from changes in power supply
status.
Table 7-12: Status Enable Register
BIT
Status name
0 (LSB)
Constant Voltage
1
Constant Current
2
No Fault
3
Fault active
4
Auto-Restart enabled
5
Fold enabled
6
Spare
7(MSB)
Local Mode
4.Status Event Register
The Status Event Register will set a bit if a change in the power supply status occurs and it is
enabled. The register is cleared when the "SEVE?" or "CLS" commands are received. A change
in this register will generate SRQ.
Table 7-13: Status Event Register
Status
BIT
name
0 (LSB)
Constant Voltage
1
Constant Current
2
No Fault
3
Fault active
4
Not used
5
Not used
6
Not used
7(MSB)
Local Mode
Status symbol
Bit Set condition
CV
User command:
CC
"SENA nn" is
received,
NFLT
where nn is
hexadecimal bits.
FLT
AST
Always zero
Always zero
FDE
Always zero
Spare
"SENA nn"
LCL
command
Status
Bit Set condition
symbol
Changes in status
CV
occurs and it is
enabled.
CC
The change can
set a bit, but when
NFLT
the change clears
the bit remains
FLT
set.
0
Always zero
0
Always zero
Always zero
0
Unit is set to Local
LCL
by pressing front
panel REM/LOC
button.
60
Bit reset condition
User command: "SENA nn"
is received, where nn is
hexadecimal bits.
If "nn"=00, no SRQ is sent
when there is a change in
Status Condition Register.
Always zero
Always zero
Always zero
"SENA nn"
command
Bit reset condition
Entire Event Register is
cleared when user sends
"SEVE?" command to read
the register.
"CLS" and power-up also
clear the Status Event
Register. (The Fault Event
Register is not cleared by
RST)