Global Output Commands - Nemic-Lambda TDK-Lambda Genesys GEN6-100 Manual

Programmable regulated power supplies
Table of Contents

Advertisement

NOTES:
1. In Advanced parallel mode (refer to Sec. 5.15.2), "n" is the total system current.
2. In Advanced parallel mode, "MC?" returns the Master unit current multiplied by the number of
slave units.

7.7.6 Global output commands

1. General
All supplies, even if not the currently addressed supply, receiving a global command will execute
the command. No response to the PC issuing the command will be returned to the PC. The PC
issuing the command will be responsible to delay and any other communications until the
command is execute. 200 Ms minimum is the suggested delay.
If the command contains an error, out of range values for example, no error report will be sent to
the issuing PC.
Reset. Brings the Power Supply to a safe and known state:
Output voltage: 0V, output current: 0A, OUT: Off, Remote: RMT 1'
GRST
AST: Off
1.
The conditional register (FLT and STAT) are updated. Other registers are not changed.
Non-Latching faults (FB, OVP, SO) are cleared, OUT fault stays.
Sets the output voltage value in volts. The range of voltage values is shown in Table 7-3.
2.
GPV n
'n' may be up to 12 char plus dec. pt
Program the output current value in amperes. The range of current values is shown in
GPC n
3.
Table 7-4. 'n' may be up to 12 char plus dec. pt
Turns the output to ON or OFF:
"OUT 1/ON" = turn on
4.
GOUT
"OUT 0/OFF"= turn off, clears CV and CC bits in the Status Condition (STAT)
OUT ON will respond with "E07' if the output cannot be turned on because of a latching
fault (OTP< AC, ENA, SO) shutdown.
Save present settings. Same settings as power-down last settings listed in Error!
Reference source not found. Except the address and Baud rate are not saved
5. GSAV
Saves to the RAM. These settings are erased when the supply power is switched off and
the new 'last settings' are saved.
Recall last settings. Settings are from last power-down or from last 'SAV' or 'GSAV'
GRCL
6.
command. Address and Baud rate are not recalled so communication is not interruped.
Table 7-3: Voltage programming range
Model
Minimum
Rated Output Voltage (V)
8
0.000
10
00.000
15
00.000
20
00.000
30
00.000
40
00.000
50
00.000
60
00.000
80
00.00
100
000.00
150
000.00
300
000.00
600
000.00
Maximum
(V)
(V)
8.000
10.000
15.000
20.000
30.000
40.000
NOTE:
50.000
The power supply can accept values higher by 5% than
60.000
80.00
the table values, however it is not recommended to
100.00
program the power supply over the rated values.
150.00
300.00
600.00
OVP:Max,
55
UVL:0.