Table 4-1: Front Panel controls and indicators
Number Control/Indicator
4
CURRENT display
5
CURRENT indicator Green LED, lights for Constant-Current mode operation.
CURRENT control
6
7
OUT button
OUT indicator
8
9
REM/LOC button
10
REM/LOC indicator
FOLD button
11
12
FOLD indicator
13
OVP/UVL button
14
PREV/
Description
4 digit, 7-segment LED display. Normally displays the
output current. When the PREV button is pressed, the
display indicates the programmed setting of output
current.
High resolution rotary encoder for adjusting the Output
Current. Also selects the Baud-Rate of the
communication port.
Main function
set the output On or Off. Press to reset and turn On the
output after OVP or FOLD alarm events have occurred.
Auxiliary function
"Auto-Restart" modes. Press and hold OUT button to
toggle between "Safe-Start" and "Auto-Restart".The
VOLT display will cycle between
Releasing the OUT button while one of the modes is
displayed, selects that mode.
Green LED, lights when the DC output is enabled.
Main function
unit into Local (REM/LOC button is disabled at Local
Lockout mode).
Auxiliary function
Press and hold REM/LOC for 3sec. to set the Address
with the VOLTAGE encoder and the Baud Rate with the
CURRENT encoder.
Green LED, lights when the unit is in Remote mode.
Foldback protection control.
- Press FOLD to set Foldback protection to On.
- To release Foldback alarm event, press OUT to
enable the output and re-arm the protection.
- Press FOLD again to cancel the Foldback protection.
Green LED, lights when Foldback protection is On.
Over Voltage Protection and Under Voltage limit setting.
- Press once to set OVP using VOLTAGE encoder ( the
current display shows "OUP" )
- Press again to set the UVL using VOLTAGE encoder
( the current display shows "UUL" ).
Main function
voltage and current limit setting. For 5 sec. the display
will show the setting and then it will return to show the
actual output voltage and current.
Auxiliary function
button
PREV button to toggle between "Locked front panel"
and "Unlocked front panel". The display will cycle
between "LFP" and "UFP". Releasing the PREV button
while one of the modes is displayed, selects that mode.
: Output ON/OFF control. Press OUT to
: Selects between "Safe-Start" and
: Go to local. Press REM/LOC to put the
: Address and Baud Rate setting.
: Press PREV to display the output
: Front Panel Lock. Press and hold
28
"SAF" and "AU7".
Section
5.2.2
7.2.4
5.6
5.11
7.2.5
7.2.2
7.2.4
5.5
5.3
5.4
5.17