ELECTRIC/PULL   ( RECOIL)   S TART   M ODELS:  
5. Using   p rovided   k ey,   t urn   t he   k ey   s witch   t o   t he   " ON"   p osition.     R otate   t he   k ey   o ne  
more   p osition   t o   t he   " START"   p osition   i n   o rder   t o   e ngage   t he   s tarting   m otor.    
Hold   k ey   s witch   i n   t he   " START"   p osition   u ntil   e ngine   s tarts   f or   N O   M ORE   t han   1 0  
engine   r otations.     I f   t he   e ngine   d oes   N OT   s tart   r epeat   p rocedures   b eginning   w ith  
Step   O ne   ( 1).  
6. Once   t he   e ngine   r uns   f or   3 -­‐5   s econds,   p ush   t he   c hoke   p in   i n   t o   d isengage.  
 
NOTE   ( all   m odels):     I f   g enerator   d oes   n ot   s tart   w ithin   t hree   p ulls,   c heck   t he   c rankcase  
oil   l evel.     T he   e ngines   " Low   O il   A larm   S ystem"   m ay   b e   a ctivated   a nd   p reventing   t he  
engine   f rom   s tarting.  
 
 
CONNECTING   E LECTRICAL   L OADS:  
1. Ensure   e ngine   i s   s tarted   b efore   p lugging   i n   a ny   e lectrical   a ppliance.  
2. Plug   i n   d esired   1 20   V olt   l oads   t o   t he   1 20   V olt   U -­‐Ground   a nd   2 40   V olt   l oads   t o   t he  
240   V olt   r eceptacles.     A lways   p lug   a ppliances   i nto   t he   g enerator   w ith   a ppliance  
in   i ts   " OFF"   p osition.  
3. Plug   i n   1 2V   D C   l oad   t o   t he   D C   r eceptacle.     D C   a nd   A C   p ower   m ay   b e   u sed  
simultaneously.     C ircuit   B reaker   m ay   n eed   t o   b e   r e-­‐set   b efore   u sing   1 2V  
receptacle.     W hen   c harging   1 2V   b atteries,   i nsert   t he   c harging   p lug   i nto   t he   D C  
socket   a nd   t hen   c onnect   t he   t erminals   t o   t he   b attery.     A fter   c harging   i s  
complete,   r emove   b attery   t erminal   f irst,   t hen   u n-­‐plug   c harging   p lug   f rom  
generator.     R emove   t he   g round   w ire   o f   C ar   B atteries   p rior   t o   c harging   a nd   r e-­‐
connect   a fter   c harging   i s   c omplete   t o   a void   s hort   c ircuit   o r   s park.  
4. Do   N OT   c onnect   2 40   V olt   l oads   t o   t he   1 20   V olt   r eceptacles.  
5. Only   c onnects   s ingle-­‐phase   6 0   H ertz   l oads.  
6. DO   N OT   O VERLOAD   T HE   G ENERATOR.     F OLLOW   T HE   P ROVIDED   " GENERATOR  
WATTAGE   R EFERENCE   W ORKSHEET"   T O   D ETERMINE   T HE   R UNNING   A ND  
STARTING   W ATTAGE   O F   Y OUR   E QUIPMENT,     R EFER   T O   T HE   P RODUCT  
SPECIFICATIONS   T O   E NSURE   Y OUR   G ENERATOR   W ILL   O PERATE   T HE   D ESIRED  
EQUIPMENT.      
NOTE:     U se   t he   r unning   a nd   s tarting   w attage   p rovided   b y   t he   e quipment   m anufacturer  
if   a vailable.     I f   n ot   a vailable,   u se   p rovided   " Generator   W attage   R eference   W orksheet."  
Operation   o f   G enerator
HOW   T O   U SE   Y OUR   G ENERATOR  