Table of Contents Preface ....................... Accessories and Replaceable Parts ................Documentation ....................General Safety Summary ..................To Avoid Electrical Shock or Fire ................If Safety Features Are Impaired................... Compliance Information ................... EMC Compliance ....................Safety Compliance.................... Environmental Considerations ................Operating Requirements ..................Electrical Ratings .....................
Page 6
Table of Contents 连接器 ....................输入连接器.
Preface This document contains the following information: A list of standard and optional accessories A list of replaceable parts Important safety precautions to avoid injury and prevent damage to this product or any products connected to it EMC (electromagnetic compliance), safety, and environmental standards with which the instrument complies Voltage, power, and environmental requirements to use the product Battery pack safety information and installation instructions...
Page 8
Preface Tektronix part Standard and Optional Accessories Standard Optional number THS3000 SERIES OSCILLOSCOPE DOCUMENTATION KIT 020-3086-xx This kit contains this printed manual (071-2963-XX) and a CD (063-4379-XX) containing various user documents. (See page 4, Documentation.) THS3000 SERIES OSCILLOSCOPE 7 HOUR LI-ION BATTERY...
Page 9
To reduce risk of fire and shock, use the certified power cord provided with the product when using the product without battery power. Service Options You can order the following service options for your instrument. Option Tektronix part number Service 3 year calibration service options 5 year calibration service...
The following table lists some of the documentation that is available for this product and shows where you can find it: in a printed manual, on the product documentation CD-ROM, or on the Tektronix Web site at www.tek.com. Table 1: Product documentation...
General Safety Summary General Safety Summary This manual contains information and warnings that must be followed by the user to ensure safe operation and to keep the instrument in a safe condition. Use of this equipment in a manner not specified by the manufacturer may impair protection provided by the equipment.
Page 12
General Safety Summary Recharge Batteries Properly. Recharge batteries for the recommended charge cycle only. Use Proper AC Adapter. Use only the AC adapter specified for this product. Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry.
42 V peak (30 VRMS) or 60 V DC, observe the following warnings: Use only insulated voltage probes, test leads, and adapters supplied with the product, or indicated by Tektronix as suitable for the THS3014 and THS3024 products.
If Safety Features Are Impaired Examine the case before you use the product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals. Do not work alone. Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flame resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed.
IEC 61000-4-6. Conducted RF immunity IEC 61000-4-11. Voltage dips and interruptions immunity EN 61000-3-2. AC power line harmonic emissions EN 61000-3-3. Voltage changes, fluctuations, and flicker European contact. Tektronix UK, Ltd. Western Peninsula Western Road Bracknell, RG12 1RF United Kingdom This product is intended for use in nonresidential areas only.
Page 16
Compliance Information Australia / New Zealand Complies with the EMC provision of the Radiocommunications Act per the following standard, in accordance with ACMA: Declaration of Conformity – EMC CISPR 11. Radiated and Conducted Emissions, Group 1, Class A, in accordance with EN 61326-1 and EN 61326-2-1. THS3000 Series Oscilloscopes Installation and Safety Instructions...
Compliance Information Safety Compliance EC Declaration of Compliance was demonstrated to the following specification as listed in the Official Journal of the European Communities: Conformity – Low Voltage Low Voltage Directive 2006/95/EC. EN 61010-1: 2001. Safety requirements for electrical equipment for measurement control and laboratory use.
Page 18
Compliance Information be expected. This location is a typical office/home environment. Temporary condensation occurs only when the product is out of service. Pollution Degree 3. Conductive pollution, or dry, nonconductive pollution that becomes conductive due to condensation. These are sheltered locations where neither temperature nor humidity is controlled.
(WEEE) and batteries. For information about recycling options, check the Support/Service section of the Tektronix Web site (www.tek.com). Battery Recycling. The included THSBAT lithium-ion rechargeable battery pack must be recycled or disposed of properly.
Page 20
Compliance Information Restriction of Hazardous This product is classified as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS Directive. Substances THS3000 Series Oscilloscopes Installation and Safety Instructions...
WARNING. Fire can cause personal injury and/or property damage. To prevent risk of fire, do not use any AC adapter with this product other than Tektronix part number 119-7900-XX, which was shipped with this instrument. Battery Power This instrument is powered by the THSBAT, a 10.8 V DC custom UL recognized...
Operating Requirements Environmental Ratings Table 3: Environmental performance Category Standards or description Temperature Operating 0 °C to +40 °C (+32 °F to +104 °F), with battery 0 °C to +50 °C (+32 °F to +122 °F), without battery Nonoperating –20 °C to +60 °C (–4 °F to +140 °F) Instrument must be acclimatized before use.
Ch 4. Green safety insulated BNC Power Connector The power connector allows you to use an external power source to power the instrument. This instrument can only be safely operated using Tektronix part number 119-7900-XX, which is an 18 V DC output power adapter. WARNING.
Page 24
Connectors USB Connector The instrument has a USB port that allows you to connect an external memory device to the instrument for data storage. USB connector Mini-USB Connector The instrument has a mini-USB type B port that allows you to connect a PC to the instrument for remote control and data transfer using OpenChoice®...
Seek medical advice if a battery or part of it was swallowed. Recommendations For The battery pack must be charged before use. Use only Tektronix approved power adapters or external chargers to charge the battery pack. Refer to the Safe Use of Battery Pack battery charger manual for proper charging instructions.
Page 26
Do not use any charger other than that specifically provided for use with this equipment. Do not use any battery pack other than that designed or recommended by Tektronix for use with this product. Take careful notice of correct placement of the battery in the product or the external battery charger.
Page 27
(See page 13.) WARNING. To reduce risk of fire or shock, do not use any battery but the battery Tektronix shipped with this product. Only use the THSBAT battery pack with this product. When handling the battery pack, take the following precautions: Do not disassemble, crush, or puncture a battery.
Getting Started Battery Installation Read the battery pack safety information before installing the battery pack. To install the THSBAT battery pack, follow these steps: 1. Place the instrument face down on a flat surface. 2. Check that the tilt stand is closed. 3.
Page 29
Getting Started 4. Remove the battery cover from the instrument. 5. Insert the THSBAT battery pack into the instrument, aligning the contacts on the battery with the contacts on the instrument. 6. Replace the battery cover. 7. Lock the battery cover screws by turning the screws 90° to the right so that the screw slats are vertical.
Getting Started AC Power Adapter Connection To use the external power source, connect the AC adapter (Tektronix part number 119-7900-XX) and power cord that was shipped with this instrument as follows. 1. Connect the power cord to the AC adapter.
Getting Started Power On and Power Off Procedures After you have installed the battery or connected the AC adapter to the instrument, turn it on and off as follows. Power On 1. If you are using a battery pack only, go to step 2. If you are using an external power source, check that the AC power adapter is connected to the instrument and that the adapter is connected to a power cord that is plugged into a properly grounded power outlet.
Getting Started Front Panel Controls NOTE. Some of the controls that this section covers are option dependant. For a list of the options that are installed on your instrument, press the Utility button and select View Options. Layout and Usage The front panel elements shown below are described in the table that follows.
Getting Started Control Element or Group Description Zoom (magnifying glass) Press to magnify a particular area of the waveform. Use the arrow keys, the vertical position keys, or the horizontal position and scale keys to decrease and increase the time/div, or to position the waveform.
Page 34
Getting Started 9. You will see the rising edge of a square wave on the display (approximately 500 Hz). This is the signal used to calibrate the probe. (See the THS3000 Series Oscilloscopes User Manual for probe calibration information). (See Figure 1.) 10.
For more detailed information about taking floating measurements, see the THS3000 Series Oscilloscopes User Manual. You will find it on the product documentation CD that was shipped with your instrument or on the Tektronix Web site at www.tek.com/manuals. Many handheld oscilloscope products have the architecture shown below, which shares a common reference for the oscilloscope channels.
Page 36
Getting Started Attach the Reference If you are using all four of the oscilloscope channels, you must attach the probe reference lead for each channel directly to your circuit. These attachments are Leads Correctly required because the oscilloscope channels are electrically isolated; they do not share a common chassis connection.
感電や火災を避けるために 感電や火災を避けるために 警告: 感電や火災を避けるために、製品の入力端子が 42 V ピーク(30 VRMS) または 60 V DC より高い電圧に接続されている場合は、以下の警告を守って ください。 製品に付属しているか、または当社が THS3014 型および THS3024 型製 品用に指定する、絶縁された電圧プローブ、テスト・リード、およびアダプタ のみを使用してください。 使用する前に、電圧プローブ、テスト・リード、およびアクセサリが機械的に 損傷を受けていないことを点検し、キズがある場合は交換してください。 使用しない電圧プローブ、テスト・リード、およびアクセサリはすべて取り外 してください。 電源アダプタは常に、製品に接続する前に最初に AC コンセントに差し込 んでください。 30 V AC RMS、42 V AC ピークまたは 60 V DC より高い電圧には触れな いでください。...
動作の要件 動作の要件 このセクションでは、製品を安全かつ正しく使用するために理解しておくべき電 気的、環境的、物理的な仕様について説明します。詳細については、『THS3000 シリーズ・オシロスコープ・ユーザ・マニュアル』の製品仕様を参照してください。 電気定格 表 10: 電気定格 カテゴリ 規格または説明 オシロスコープ 最大入力電 600 V CAT III/1000 V CAT II 力(AC または BNC 端子への DC rms) 直接入力 300 V CAT III 電圧プローブ THP0301 型使 用時 プローブ・チッ 300 V CAT III/600 V CAT II プ間...
Page 82
コネクタ USB コネクタ 本器の USB ポートに外部メモリ・デバイスを接続すると、データ・ストレージとし て使用することができます。 USB コネクタ ミニ USB コネクタ 本器のミニ USB タイプ B ポートに PC を接続すると、OpenChoice® Desktop を 使用してリモート・コントロールとデータ転送を行うことができます。 ミニ USB コネクタ 本器のプローブ調整コネクタを使用すると電圧プローブを校正することができ プローブ調整コネクタ ます。コネクタ上のプローブ校正信号により、プローブを本器の入力チャンネ ルに合わせて校正することができます。 プローブ調整コネクタ THS3000 Series Oscilloscopes Installation and Safety Instructions...