CLEARANCES
Top
Bottom/Ground
Front
Back
Sides (Left and Right)
Vent
(Internal/Indoor Models)
Front Exhaust
(External/Outdoor Models)
INSTALLATION LOCATION CHECKLIST
Use this checklist to ensure you have selected the correct location for the water heater.
The water heater is not exposed to corrosive compounds in the air.
The water heater location complies with the required clearances.
The planned combustion air and exhaust termination locations meet the required clearances.
The water supply does not contain chemicals or exceed total hardness that will damage the heat exchanger.
A standard 3 prong 120 VAC, 60 Hz properly grounded wall outlet (for internal/indoor models) or other 120 VAC,
60 Hz source is available.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
14
2 in. (51 mm)
0 in from vent components
12 in. (305 mm)
0 in.
Clearance for servicing is
24 in. (610 mm) in front of
water heater
0 in.
2 in. (51 mm)
Add 0.25 in. (6.35 mm) for
recess box
0 in.
24 in. (610 mm)
INTERNAL (INDOOR)
MODELS
Top
Front
Side
Bottom
Rinnai Tankless Water Heater Installation and Operation Manual
EXTERNAL (OUTDOOR)
MODELS
Top
Side
Front
Bottom