Philips Saeco INTELIA Service Manual page 51

Table of Contents

Advertisement

INTELIA-INTUITA
New version with a solenoid valve
Press STAND_BY "
Operational check - solenoid valve and pump
Initial status
If the dreg drawer is in position and the side hatch closed, the EV cannot
be done. If it is not in the right position, a warning message is shown on
the display, which turns yellow.
Press the espresso button to activate the solenoid valve
The indication next to EV1 changes from "OFF" to "ON".
You can hear the "click" of the solenoid valve.
Press the coffee button to activate the solenoid valve
The indication next to EV2 changes from "OFF" to "ON".
You can hear the "click" of the solenoid valve.
Press the aroma button to activate the pump
The water is dispensed from the steam pipe IMP indicates an increasing
number of pulses. L/H must be between 10 and 18.
ERROR: The back-lit green display changes to red and the pulse remains
0 even if water comes out of the steam pipe, check the wiring on the flow
meter (JP5). If water does not come out of the steam pipe, check the pump
and the pump wiring (JP24).
Press the ESPRESSO button to activate solenoid valve EV1.
The solenoid valve is activated and the indication to the right of EV1 changes
from "OFF" to "ON".
ERROR:
The pulses remain at 0, the display turns red, this means there is an error
in the water circuit. If water is coming out of the coupling,it means there is
an error in the flow meter or in its wiring in the Control Board/Power Board
(JP5). If no water is coming out, check the pump, the connected water
circuit, or the pump wiring (JP24).
" to move to the next screen