INTELIA-INTUITA
Press STAND_BY "
Operational check - microswitches and sensors
Initial status
If you insert a full drip tray the TANK-H20 indicator must change from "N" to
"Y".
ERROR condition:
If the indication does not change, check the capacitive sensor and relative wir-
ing (JP23).
Insert grounds drawer
The DREG indicator must change from "N" to "Y"
ERROR condition:
If the indication does not change, check the microswitch on the dreg drawer
and relative wiring (JP16).
Close the side hatch (the dreg drawer must be inserted)
The DOOR indicator must change from "N" to "Y"
ERROR condition:
If the indication does not change, check the Microswitch on the hatch and
relative wiring (JP14), make sure that the dreg drawer is correctly in position.
Insert the brewing unit
The BU-P indicator must change from "N" to "Y"
(this step takes 2-3 sec)
ERROR condition:
If the indication does not change, check the brewing unit microswitch and
relative wiring (JP16)
Insert the brewing unit
The TRAY indicator must change from "N" to "Y"
ERROR condition:
If the indication does not change, check the brewing unit microswitch and
relative wiring (JP04)
" to move to the next screen
Operational check - impuls Milk
NOT USED