MANUAL PCE-IT 100

Advertisement

loading

Summary of Contents for PCE Instruments PCE-IT 100

  • Page 1 All manuals and user guides at all-guides.com www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk http://www.industrial-needs.com/ MANUAL PCE-IT 100...
  • Page 2 All manuals and user guides at all-guides.com info@tursdaletechnicalservices.co.uk Safety symbols: ..............................3 1.SPECIFICATIONS ............................4 1.1General Information Environment conditions: ................... 4 Maintenance & Clearing: .......................... 4 Display: Large LCD with dual display ...................... 4 Measurement Range ..........................4 Sampling Rate ............................4 Zero Adjustment: ............................
  • Page 3: Safety Information

    All manuals and user guides at all-guides.com info@tursdaletechnicalservices.co.uk SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. To avoid damages to the instrument do not apply the signals which exceed the maximum limits shown in the technical specifications tables.
  • Page 4: Specifications

    All manuals and user guides at all-guides.com info@tursdaletechnicalservices.co.uk 1.SPECIFICATIONS 1.1General Information Environment conditions: ① Installation Categories ② Pollution Degree 2 ③ Altitude up to 2000 meters ④ Indoor use only ⑤ Relatively humidity 80% max. ⑥ Operation Ambient 0~40ºC Maintenance & Clearing: ①...
  • Page 5 All manuals and user guides at all-guides.com info@tursdaletechnicalservices.co.uk 1.2 Electrical Specifications Accuracies are specified in the way: ±(…% of reading +…digits) at 23ºC±5ºC,below 80% RH. OHMS Range Resolution Accuracy Max. open Overload Circuit Voltage Protection 40.00Ω 0.01Ω 5.8V +(1.2%+3) 250Vrms 400.0Ω...
  • Page 6: Parts And Controls

    All manuals and user guides at all-guides.com info@tursdaletechnicalservices.co.uk 2. PARTS & CONTROLS Insulation Tester DT-5505 1.Digital Display BA R ( 1) (1 ) POL 1 2.Data Hold Button; MAX/MIN OH M L OB AT (1 ) (2 ) 3.Lock Button POL2 ( 2 ) (2 )
  • Page 7 All manuals and user guides at all-guides.com info@tursdale technicalservices s.co.uk 2-5 B Buttons and a dis isplay Ind dicators Button HOLD D/MAX.MIN : Instan t-pressing t the “HOLD” ” button the e 1st time, t the current values will l be hold in n the prima ary display.,...
  • Page 8 All manuals and user guides at all-guides.com info@tursdale technicalservices s.co.uk 3. IN NSULAT TION RE ESISTA NCE ME EASUR EMENT a)Tur n the funct tion switch from the “ “OFF” posi tion to the left(4000 0 MΩ/1000V V---4000/ M MΩ500V---4 4000 MΩ...
  • Page 9: Battery Saver (Sleep Mode)

    All manuals and user guides at all-guides.com info@tursdaletechnicalservices.co.uk 6.BATTERY SAVER (SLEEP MODE) The meter will automatically enter the “sleep mode” if there is no function change or button press for 10minutes, but it works as soon as you turn the rotary function switch or push down any button. 7.POWER TOOLS AND AMALL APPLIANCES This test would also apply to other similar equipment that has a line cord.
  • Page 10 All manuals and user guides at all-guides.com info@tursdaletechnicalservices.co.uk In this direction will find a vision of the measurement technique: http://www.industrial-needs.com/measuring-instruments.htm NOTE: "This instrument doesn’t have ATEX protection, so it should not be used in potentially explosive atmospheres (powder, flammable gases)."...