Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus
Closing the cover of the electronics compartment
1.
Screw down the cover of the electronics compartment.
2.
Turn the securing clamp 90 ° in the clockwise direction and, using an Allen key (3 mm),
tighten the screw of the securing clamp on the electronics compartment cover with
2.5 Nm.
6
Electrical connection
6.1
Connecting requirements
6.1.1
Terminal assignment
Endress+Hauser
1.
3 mm
2.
2.5 Nm
Electrical connection
A0021451