7. CAPACITY TABLES
PQHY-
Nominal
kW
49.2
Cooling
Capacity
BTU/h
168,000
Input
kW
9.33
Inlet-water temp.
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
20
30
40
50
60
Inlet-water temp. [°F]
Intake air temp.
1.2
1.1
1.0
0.9
0.8
0.7
59
61
63
65
Intake air temp. [°FWB]
PQHY-
Nominal
kW
55.1
Heating
Capacity
BTU/h
188,000
Input
kW
9.34
Inlet-water temp.
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
20
30
40
50
60
Inlet-water temp. [°F]
Intake air temp.
1.2
1.1
1.0
0.9
0.8
0.7
59
62
65
68
Intake air temp. [°FDB]
MEES19K187
P168TSLMU/YSLMU
Rated
kW
47.2
Cooling
Capacity
BTU/h
161,000
(Non-Ducted) 8.58
Input
kW
(Ducted) 9.22
Capacity
Input
70
80
90
100 110
Capacity
Input
67
69
71
73
75
P168TSLMU/YSLMU
Rated
kW
52.5
Heating
Capacity
BTU/h
179,000
(Non-Ducted) 8.60
Input
kW
(Ducted) 8.03
Capacity
Input
70
80
90
100 110
Capacity
Input
71
74
77
80
*The drawing indicates characteristic per unit.
Water volume*
1.10
1.05
1.00
0.95
0.90
9
12
15
18
21
24
Water-volume [gpm]
Water-pressure drop*
6
5
4
3
2
1
0
10
15
20
25
Water-volume [gpm]
Water volume*
1.10
1.05
1.00
0.95
0.90
9
12
15
18
21
24
Water-volume [gpm]
Water-pressure drop*
6
5
4
3
2
1
0
10
15
20
25
Water-volume [gpm]
WY-Series
Capacity
Input
27
30
33
36
30
35
Capacity
Input
27
30
33
36
30
35
82