5. Inspection
Sequemnce
Item
9
Erase mode check Erase
10
Flash check
11
LCD dust/defect
Playback
check
12
Battery low check
Movie
13
Current
Auto mode
consumption check
LCD-ON
14
Checking standby
OFF
current
5-4
Preparations for adjustment
Mode
(measurement points, subject, other)
(1) Select "Erase" -> "Erase
all" from the menu and
then press the "OK" button.
(2) Press the "OK" button
again.
(1) Set the flash mode to
FORCED FLASH.
(2) Check that the flash pops
up when a picture is taken.
(1) Insert a standard xD-
Picture card.
(2) Play back a completely
black image.
(3) Play back a completely
white (75%) image.
(4) Change the setting with the
EVF/LCD button.
(1) Connect the power supply
jig to the Battery terminal.
(2) Set the power supply
voltage.
(3) Set the Mode dial to Movie
or Camera mode and turn
the camera on.
(4) Set the pre-end voltage.
(5) Set the end voltage.
(1) Connect the power supply
jig to the Battery terminal.
(2) Set the power supply
voltage.
(3) Set the Mode dial to AUTO
and turn the camera on.
(4) After the LCD live image
appears, check the current
consumption.
(1) Connect the power supply
jig to the DC_IN terminal.
(2) Set the power supply
voltage.
(3) Check the standby current
when the power is turned
OFF.
Confidential: FUJIFILM Service Center Use Only
FinePix S5800/S800 Service Manual
Method of adjustment
(VRs, waveforms, required values)
(1) Check that an erase
message such as the
following appears:
Japan: "
OK?"
Overseas: "ERASE ALL
OK?"
China: "
OK?"
(2) Check that the recorded
images are erased.
(1) Press the 4-way button
(right) and check that
** appears on the LCD
monitor.
(2) Check that there are no
noticeable dust flecks or
stains (bright spots) on the
screen.
(3) Check that there are no
noticeable dust flecks or
stains (smears, flashing
points, etc.) on the screen.
(4) Play the above 2 frames
and perform the same
checks.
(2) 5.0 ± 0.1 V
(3) Check that the camera
starts up normally.
(4) 4.6 ± 0.1 V
Check that the battery low
warning appears.
(5) 4.47 ± 0.10 V
Check that the camera
turns off.
(2) 5.0 ± 0.1 V
(4) 500 mA or less
(Stable state -> IRIS/
FOCUS does not operate)
(2) 5.0 ± 0.1 V
(3) 0.2 mA or less
Measuring
Measurement points
equipment and jigs
(VRs, positions)
ZJ00885-100
ZJ01080-100
ZJ01080-100
ZJ00580-100