Engine is without oil in the crankcase and is equipped with a sensor for the oil level. At low
oil level engine may not start. When loading oil generator must be horizontal. The oil is poured
slowly until it spill. Do not use stayed or non-motor oils (hydraulic, transmission, etc.). Always
check the oil level before starting or sudden stopping of the engine.
Shortage of oil can cause engine damage, excess oil leads to spotting the candle.
IMPORTANT !!!
The engine is not loaded with fuel. The engine is a four stroke!!! Do not add oil to petrol !!!
Pour fresh unleaded gasoline in the tank by using the funnel or tube with a suitable plug
(not included in the fittings of the machine).
Do not use stayed fuels.
Use the output DC.
Only used for battery charging 12V.
Using a charging cable to connect the battery output DC. The cables must be connected to
the battery as follows: connect the red cable to the positive (+) terminal and the black to the
negative (-) terminal of the battery.
Do not change this way of connection, to avoid damage to the generator or battery
Connect the cables to the battery first and then to the generator.
Remove the cables from the generator first and then from the battery.
Do not attempt to start the car while the generator is connected to the car battery, as this
could damage the generator.
DC output can be used simultaneously with the output AC.
Overload of the right current circuit, automatic fuse will switch off / will go out /. If this
happens wait a few minutes before press it to reset the circuit.
3.2. Stop the engine.
Before you stop the electric, leave it for a short time to work without load to allow the unit
to cool down.
1. In case that the generator is connected to a circuit, you must insert the key in position
"OFF" (switch labeled "CIRCUIT BREAKER")
2. Then disconnect the mechanical circuit of plug.
3. Place the ignition switch contact in "OFF" position.
4. Place the choke plate as shown on the label for final stop of the engine.
Attention! Electric generator is equipped with overload protection.
NOTE! Your generator is equipped with a tap for fuel to interrupt the supply DIRECTLY FROM
FUEL TANK TO WORK SYSTEM (located to the right of the choke valve with LABEL "FUEL").
WNEN TRANSPORTING THE GENERATOR turn the tap in possition "OFF".
5. After the start of the engine choke back to the starting
position.
ATTENTION !!! Before starting the engine, make sure
that you did not include electrical equipment to the
generator (Figure 5)
Attention!
13