Cycles
The cycle page allows you to add, edit, copy, delete, or reorder cycles.
Edit Cycle
Select anywhere on the cycle description (cycle name, target temp,
material, or target) to open the cycle details for editing.
Reorder Cycle
Select and hold to move a cycle up or down in the listing. This will change
the order it is displayed on the control.
This will duplicate the cycle.
of creating a new cycle. Copy the cycle that is closest to the cycle you want to
create and edit that cycle. If a default cycle doesn't meet your needs, select
Copy Cycle
"Add Cycle" and choose a default cycle from another application. You can
always change the cycle name in the edit section.
Delete Cycle
This will delete an existing cycle.
This will allow you to add a preset cycle from another industry or another
Add Cycle
location.
34
Part # 8533-109-001 12/21
Legend
Tip: It is easiest to edit an existing cycle instead
Cycle Settings
A cycle can be edited by clicking on the cycle name in the Cycles page. The name and language can
be customized for that specific cycle. Changing the language for a cycle will change the status, stage
names, and prompts displayed during that particular cycle.
Tip: If a location has multi-lingual employees, the same cycle can be duplicated and
programmed for different languages. For example, in a location with English and Spanish
speaking employees, program White Sheets to the desired settings. Copy that cycle, set that
cycle language to Spanish, and note the name change to Sabanas Blancas. This will allow all
employees to read the necessary prompts and descriptions on the control.
Stages
A stage can also be considered a bath, such as prewash, wash, rinse, etc. Each cycle can consist of 20
unique stages. Within each stage, the following parameters can be selected.
Setting
Options
Bath Temperature
Fill
Auxiliary Temperature
(Heated Models Only)
100F (38C) – 195F (91C)
Water Level
Injection Type 1 – 3
Detergent Flush
Softener Flush
Soap /
Chemical 1-10
Chemicals
Injection Delay
0 – 150 seconds
Injection Duration
1 – 240 seconds
Options
Description
Hot
Warm
Cold
No Fill
No Heat
Heated models only. Temperature
is programmable in 5
F / 3
C
O
O
increments.
Low
These settings can be controlled by
High
the electronic pressure sensor.
None
Three unique soap options are
available for each stage.
See optional settings for setting
chemical injection details.
If Delay Fill is ON this is the time from
when the low water level is met. If
Delay Fill is OFF this represents the
time from start of the stage to when
chemical injection begins.
The amount of time chemicals will
be injected.