11-8-3. Indoor unit (Other parts)
No.
Part name
1
Room temp. (TA) sensor
Heat exchanger (TC) sensor
2
Remote control
3
Louver motor
24BYJ48
4
Indoor fan motor
11-8-4. Outdoor unit
No.
Part name
1
Compressor
(Model : DA89X1C-23FZ)
Outdoor fan motor
2
(Model : SKF-240-20B-1)
Checking procedure
Disconnect the connector and measure the resistance value with tester.
(Normal temp.)
Temperature
Sensor
TA, TC (k )
To item of How to judge whether remote control is good or bad of the Judgment
of trouble by symptom.
Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)
Since judgment of DC motor is difficult on the single motor, refer to 10-5-1. (3)
Checking procedure
Measure the resistance value of each winding by using the tester.
Red
White
Black
Measure the resistance value of winding by using the tester.
Red
C1.5 mF
450V
N
White
Black
– 76 –
FILE NO. SVM-07008
10°C
20°C
25°C
20.7
12.6
10.0
Position
Resistance value
1 to 2
1 to 3
1 to 4
1 to 5
Position
Resistance value
Red - White
White - Black
Black - Red
Position
Resistance value
White - Black
Black - Red
For details, refer to Section 10-9.
30°C
40°C
7.9
4.5
380±40
1.1Ω
Under 20°C
260.1
235.2