Operation Description; Basic Operation; Operation Control - Toshiba RAS-10SAV-A Service Manual

Split wall type
Table of Contents

Advertisement

9-2. Operation Description

Item
1. Basic

1. Operation control

operation
Receiving the user's operation condition setup, the operation statuses of indoor/outdoor units are
controlled.
1) The operation conditions are selected by the remote controller as shown in the below.
2) A signal is sent by ON button of the remote controller.
3) The signal is received by a sensor of the indoor unit and processed by the indoor controllers as
shown in the below.
4) The indoor controller controls the indoor fan motor and louver motor.
5) The indoor controller sends the operation command to the outdoor controller, and sends/receives
the control status with a serial signal.
6) The outdoor controller controls the operation as shown in the left, and also controls the compres-
sor, outdoor fan motor and 4-way valve.
Selection of
operation conditions
ON/OFF
Signal receiving
Indoor unit control
Operation command
Serial signal send/receive
Serial signal send/receive
Outdoor unit control
Operation flow and applicable data, etc.
Remote controller
Control contents of remote controller
• ON/OFF (Air conditioner)
• Operation select (COOL/HEAT/AUTO/DRY)
• Temperature setup
• Air direction
• Swing
• Air volume select (AUTO/LOW/LOW+/MED/MED+/HIGH)
• ECO
• ON timer setup
• OFF timer setup
• Hi POWER
Indoor unit
Indoor unit control
• Command signal generating function of
indoor unit operation
• Calculation function (temperature calculation)
• Activation compensation function of indoor fan
• Cold draft preventive function
• Timer function
• Indoor heat exchanger release control
Outdoor unit
Outdoor unit control
• Frequency control of inverter output
• Waveform composite function
• Calculation function
(Temperature calculation)
• AD conversion function
• Quick heating function
• Delay function of compressor reactivation
• Current release function
• GTr over-current preventive function
• Defrost operation function
• COMFORT SLEEP
• QUIET
• PRESET
• ONE-TOUCH
Inverter
26
FILE NO. SVM-07008
Description
• Indoor fan motor
• Louver motor
~
• Compressor
• Outdoor fan motor
• 4-way valve

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents