Specifications

General

Stainless steel enclosure
All burners have flame safeguard
The valve is the modulating thermostat with on/off function with temperature selecting knob
Cast iron burner
Thermostat with manual reset limit switch
Three/four burner; Three/four combustion tube
 Oil Tank size14" X 14"

Pack Contents

The following is included:
Gas Fryer
Castors
Instruction
Fryer Restraint Chain

Gas Supply Requirements

Gas Type
Natural Gas (G20)
Models
Single burner
Heat Input
Heat Total
Manifold
Pressure
Min. Inlet
Supply
Pressure
Main burner
injector orifice
Pilot Injector
Orifice Size
Gas Connec-
tion
The burner operating pressure is to be measured at the gas control valve outlet test point with one burner
operating at 'High' setting. The operating pressure must be in accordance with the requirements of the
pressure in the above table.
DC319-N
8.8KW
26.4 KW
17 mbar
20mbar
#43
(Ø 2.28mm)
Ø 0.021"
(Ø 0.53mm)
¾" BSP
Propane (G31)
DC319-P
8.8KW
26.4 KW
36 mbar
37 mbar
#53
(Ø 1.51mm)
Ø 0.01"
(Ø 0.25mm)
¾" BSP
4
Butane (G30)
DC319-P
8.8KW
26.4 KW
29 mbar
30 mbar
#53
(Ø 1.51mm)
Ø 0.01"
(Ø 0.25mm)
¾" BSP