Thermal Cut-out Reset
The appliance is fitted with a Thermal Cut-Out safety switch. Should the temperature exceed safe levels
the appliance will automatically cut off power.
The thermal Cut-out switch is located on the front of the unit. To reset the appliance after a sufficient
cool-down period:
1. Unscrew the reset switch cover.
2. Press the small reset switch down until it clicks, using a blunt pointed instrument.
3. The appliance is now reset and can be used as normal.
Cleaning, Care & Maintenance
The Fryer should be cleaned after each day's operation; however it may require cleaning
more often, depending on the volume of frying carried out.
Failure to clean the appliance regularly may result in premature activation of the thermal
cut-out switch.
Do not use any abrasive cleaning agents on the appliance.
1. Switch off the power and disconnect from the power supply.
2. Allow the appliance and oil to cool before cleaning.
3. Check the temperature with a suitable probe thermometer. 40ºC is the MAXIMUM temperature at
which oil should be removed. Empty the oil tank by opening the drainage tap on the front of the unit.
Note: If the remaining oil is to be reused, filtering it before storage will extend the oil's
cooking life.
4. Remove the heaters before cleaning takes place. The lifting mechanism cannot be immersed in
water, but can be wiped down with a damp cloth.
5. Use a suitable detergent to clean the oil tank. Let it dry well, ensuring no moisture enters the inside
of the appliance.
6. The main body can also be cleaned with warm soapy water.
7. After cleaning as above, please use a dry cloth to clean the appliance to ensure there is no water on
the heating element and in the oil tank.
Clean removable parts
Use warm, soapy water and a soft brush to clean the lids and baskets.
Dry thoroughly.

Technical Specifications

Note: Due to our continuing program of research and development, the specifications herein may be
subject to change without notice.
Model
Voltage
CU476
400V 3N~,
50-60Hz
CU477
CU476-CU477_EN_A5_v1_20231020.indb 7
CU476-CU477_EN_A5_v1_20231020.indb 7
Power
Temperature
(Max.)
Range
6kW
60ºC - 190ºC
12kW
60ºC - 190ºC
Capacity
Dimensions
(Max.)
h x w x d (mm)
8L
280 x 400 x 600
2 x 8L
280 x 600 x 600
EN
Net
Weight
20kg
34kg