ATTENTION
Please read the following instructions carefully to ensure that mounting operation will be carried out correctly. These instructions
should be properly preserved for future reference.
CAUTION
1. The product must be installed by qualified technicians. The power supply must be cut before installation.
2. The installation wiring must be 3 x 1.0 - 2.5 mm² at least and wired in accordance with the latest IEE electrical regulations or the national requirements.
3. Cut the power supply before replacing battery. (Recommend type of cable is H05RN-F)
4. Do not touch the electronic circuit and its components.
5. When fixture is unable to maintain the 1 hour duration under battery operation, then the battery must be replaced.
6. Contact an authorised technical service center for the replacement of the battery and use only original manufacturer spare parts for any
other repairs.
7. Code for identification of battery production date: for instance 2150 --- year 2021, week 50.
8. Do not touch the LEDs while installing or maintaining.
9. This product contains a light source of energy efficiency class E.
10. The charge of the battery will decrease by self-discharge if not connected to mains supply. Prolonged periods without voltage can damage the
battery. Battery warranty claims, as a result of such abuse, are specifically EXCLUDED from warranty terms.
11. On many building sites, power circuits may be cut off in an uncontrolled and repetitive basis during construction. As a result, any unit on these
circuits, will have their batteries discharged or 'cycled' . Excessive battery cycling will reduce through-life performance and may lead to premature
battery failure. Battery warranty claims, as a result of such abuse, are specifically EXCLUDED from warranty terms.

TECHNICAL DATA

Supply voltage: AC 220-240V 50/60Hz
Light source: LED SMD2835
Battery: Ni-Cd 7.2V Duration: 1 hour
Operating temperature: -10°C – +50°C
(Sensor version: -10°C – +40°C )
Electrical safety class: Class I

TECHNICAL INFORMATION

Article no.
Power
Light output
Rockdisc III
40009072
23.5W
2000Lm / 1300Lm / 900Lm
40009073
24.5W
2000Lm / 1300Lm / 900Lm
MICROWAVE SENSOR - DESCRIPTION
Detection zone max. (d x h): 12m x 6m
Detection sensitivity: 50% or 100%, adjustable
Hold time: 5sec - 10min, adjustable
Daylight on: 5 - 50Lux, adjustable or disabled
Daylight off: 25 - 150Lux, adjustable or disabled
Stand-by period (low light level): 0 sec - +∞ min, adjustable
Stand-by dim level: 10% or 25%, adjustable
Ceiling mounting height: 6m max.
Motion detection (threshold): 0.3 ~ 3m/s
Detection angle: 150° (wall installation),
360° (ceiling installation)
10
Rockdisc III
MW
Article no.
sensor
Rockdisc III Semi shielded
-
40009077
Yes
40009078
Wall mounting detection area (m)
Suggested installation height: 2m
Walking speed: 0.3m/s
www.prolumia.com
340
Semi shielded
Power
Light output
23.5W
1600Lm / 1000Lm / 700Lm
24.5W
1600Lm / 1000Lm / 700Lm
Ceiling mounting detection area (m)
Suggested installation height: 3m
Walking speed: 0.3m/s
340
Rockdisc III
MW
sensor
-
Yes

Advertisement