MICROWAVE SENSOR - PARAMETER SETTINGS
Detection Area
This determines the effective range of the motion detector and is set
with DIP switches on the driver. Note that reducing the sensitivity will
also narrow the detection range.
Daylight
With this setting it can be determined at what daylight level the
luminaire will or will not be switched on when motion is detected.
The photocell functionality can also be disabled.
Stand-by Dim level
Adjustment of the luminous flux with dimmed light level.
When the DIP switch is set to +∞ on 'Stand-by period' ,
the default setting is 10% and can't be changed.
Hold Time
This determines the time the fixture remains at 100% and is set with
DIP switches on the driver. The walk test (5s) setting is useful when
installing the fixture to establish correct operation and range.
Stand-by period
With the + ∞ setting, the fixture will light up dimmed based on
the setting of
detection, the light level goes to 100% during the hold time.
Motion
detected
www.prolumia.com
and the amount of ambient light. With motion
100%
10% / 25%
Hold time
Standby time
(5s-10min)
(0s, 10min,
30min, +∞)
Person leaves
the area