Programming the transmitter / channel
Commissioning
(connecting a tubular motor or a venetian blind drive)
!
P R E R E Q U I S I T E !
The Revio-868/-915 is installed.
(→ see chapter Connection RM/JA)
The end positions must be set.
The jumpers (tubular motor/venetian blind drive connection/vene-
tian blind in pulse mode) must be installed before programming
of the transmitters.
1. After restoration of power or by pressing the P button
(at least 5 s), the Revio-868/-915 is in programming mode for
5 minutes.
2. Programme the transmitter (→ see transmitter instructions).
Programming additional transmitters
→ see transmitter instructions
Programming positions
→ see transmitter instructions
Approaching positions
→ see transmitter instructions
Deleting positions/deleting transmitters
→ see transmitter instructions
Disposal
Dispose of the device as specified by national regulations for dis-
posal of electronic waste (e.g. suitable collection points).
12 | EN
Ⓒ elero GmbH
Technical data / Disposal /
Notes on troubleshooting
Technical data
Nominal voltage
230 - 240 V AC / 50 to 60 Hz
Switching current
3 A
IP Code
IP 20
Permitted ambient
temperature
0 to 55 °C
Radio frequency
869,525 MHz
Transmission power
≤ 500 mW
Type of installation
Flush-mounted housing, Ø 58 mm, depth 60
mm. Corresponding surface-mounted housing
Dimensions
L 50 x W 48 x H 27 mm
Maximum number
of transmitters
16 transmitters
Conformity
Notes on troubleshooting
Fault
Cause
Drive does not run
Wrong connection
Drive runs in the
Directions are incor-
wrong direction
rectly programmed
No radio reception
• Transmitter is not
programmed
• No power supply
Bad radio
Unfavourable
reception
position of the
antenna/receiver
Ⓒ elero GmbH
Remedy
Check connection
Delete transmitter and
programme correctly
• Programme
the transmitter
• Switch on power
supply
Change the posi-
tion of the antenna/
receiver
EN | 13