D Standard Specification; B Wiring Diagram; Inspection And Maintenance Work - Overview - Vaillant electronicVED lite Operating Instructions Manual

Table of Contents

Advertisement

B
Wiring diagram
4
L1'
L2'
L3'
3
1
Safety cut-out
2
Electronic safety switch
Inspection and maintenance work – Overview
C
Note
The table below lists the manufacturer's minimum requirements with regard to inspection and maintenance. If na-
tional regulations and directives require shorter inspection and maintenance intervals, you should observe these
instead of the intervals listed in the table.
Maintenance work
Check that the product functions correctly
Descale the product
Clean the water filter in the cold water connector
Cleaning the valve's flow regulator on the draw-off point
D
Standard specification
Standard specification at 15 °C
Specific conductivity σ ≤
Specific
resistance
ρ ≥
Ω cm
mS/m
900
111
1000
100
1100
91
1200
83
1300
77
0020323586_00 Installation and maintenance instructions
U
F
θ>
1
2
L
L
L
Standard specification at 20 °C
Specific
resistance
ρ ≥
µS/cm
Ω cm
1111
800
1000
890
909
970
833
1070
769
1175
3
Printed circuit board
4
Heating element
Specific conductivity σ ≤
µS/cm
mS/m
125
1250
112
1124
103
1031
93
935
85
851
Standard specification at 25 °C
Specific conductivity σ ≤
Specific
resistance
ρ ≥
Ω cm
mS/m
735
136
815
123
895
112
985
102
1072
93
µS/cm
1361
1227
1117
1015
933
47