Gs - Get System Information; La - Lock Afi; Ld - Lock Data - AEG ARE i2 - HF Installation Manual

Compact reader
Table of Contents

Advertisement

Input format one block:
Input format multiple blocks:
Output (example):
Parameter:
PARAMETER 1
1 or 2 characters
PARAMETER 2
1 or 2 characters
PARAMETER 3
00h
01h
5.6.4 GS – get system information
This command sends the get system information to the transponder. The answer format is described in
the ISO 15693 chapter 9.3.12. You have to do a get tag first.
Input format:
Output (example):
5.6.5 LA – lock AFI
This command locks the AFI of a transponder. You have to do a get tag first.
Input format:
Output (example):
5.6.6 LD – lock data
This command locks the data of a block. You have to do a get tag first.
Input format:
--------------------------------------------------------------------------------41/50--------------------------------------------------------------------------------
GMS <SP> parameter 1 <CR>
GMS <SP> parameter 1 <SP> parameter 2 <CR>
parameter 3 <CR>
FUNCTION
block/start block number
FUNCTION
end block number
FUNCTION
block is not locked
block is locked
GS <CR>
0F7FAA9006000104E000201B0301 <CR>
LA <CR>
ACK <CR>
LD <SP> parameter <CR>

Advertisement

Table of Contents
loading

Table of Contents