Item
Synchronous method
Encoding method
Transmission path type
Transmission format
Error control method
Connection cable
RAS function
Number of times of
parameter registration
to EEPROM
Connectable PLC
Number of occupied
I/O points
Communication with PLC
Note
Operation indication
Accessories
MASS (Weight)
*1 Dedicated CC-Link cables and dedicated high-performance CC-Link cables cannot be used at the
same time.
Attach a terminal resistor in accordance with the cable type.
*2 When an FX
Series PLC is connected, the interface FX
2NC
*3 When an FX
Series PLC is connected, the interface FX
3UC
*4 The [RD] LED is darker as the transmission speed is faster and as the number of connected stations
is smaller.
This manual confers no industrial property rights or any rights of any other kind, nor does it
confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any
problems involving industrial property rights which may occur as a result of using the contents
noted in this manual.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of
Mitsubishi; opportunity loss or lost profits caused by faults in the Mitsubishi products; damage,
secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi;
damages to products other than Mitsubishi products; and to other duties.
This product has been manufactured as a general-purpose part for general industries, and has
not been designed or manufactured to be incorporated in a device or system used in purposes
related to human life.
Before using the product for special purposes such as nuclear power, electric power,
aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.
This product has been manufactured under strict quality control. However when installing the
product where major accidents or losses could occur if the product fails, install appropriate
backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN
JY992D93201D
Frame synchronous method
NRZI method
Bus (RS-485)
In conformance to HDLC Standard
16
12
5
CRC(X
+X
+X
+1)
Dedicated CC-Link cable/Dedicated high-performance CC-Link cable
Automatic return function
Slave station cutoff function
Error detection by link special relay/register
Approximately 10,000 times
FX
, FX
(V 2.20 or later), FX
1N
2N
Series PLC
8 I/O points of FX Series PLC (8 points in total. The ratio between inputs
and outputs is arbitrary.)
When remote I/O station is connected, 32 points per station are occupied.
By FROM and TO instructions or direct specification of buffer memory (FX
FX
) via the buffer memory
3UC
Scan method: Asynchronous mode
Automatic refresh: Not provided
Local station function: Not provided
Standby master station function: Not provided
Intelligent device station connection function: Not provided
FX
-32ASI-M AS-i master block: Cannot be connected concurrently.
2N
POWER : Lit while 24V DC is supplied from outside.
L RUN
: Lit while communication is normal.
L ERR
: Lit when communication error has occurred.
SD
: Lit while data is being transmitted.
RD
: Lit while data is being received.
Terminal resistor
For standard cable:
110 Ω, 1/2 W (color cable: brown, brown and brown), 2 cables
For high performance cable:
130 Ω, 1/2 W (color cable: brown, orange and brown), 2 cables
Special block number label
0.4 kg (0.88 lbs)
For safe use
Manual number : JY992D93201
Manual revision : D
Date
Specification
, FX
(V 2.20 or later)
3U
2NC
*4
-CNV-IF is required.
2NC
-CNV-IF or FX
2NC
: JUN. 2010
*1
*2
, FX
, FX
3G
3UC
-1PS-5V is required.
3UC
Effective JUN. 2010
Specifications are subject to
change without notice
*3
/
3U

Advertisement