Led Indication - Fichtelbahn ReadyRS Manual

Table of Contents

Advertisement

Available languages

Available languages

FichtelBahn

07. LED indication

07.1 Operating Modes
1
fast flicker
2
OFF
continuous lighting
fast flashing
3
OFF
fast flashing
4
5
All 8 LED ON
All 8 LED OFF
Flashing once
Slow flashing
07.2 Error states at module start / Status LED
10x fast flashing (1, 2, 3)
no bootloader found / no firmware update possible (contact FichtelBahn - Support)
Continuous flashing (3, 6)
No BiDiB-Unique-ID found (contact FichtelBahn - Support)
Manual ReadyRS V1.0
Manual Version 1.0
Power-ON-LED
ReadyRS is operating
BiDiB-Identify-LED
No connection to the BiDiBus
Connected to the BiDiBus
Identify - function active (see "8. Identify-Function" on page 28)
RS-LED
The RS bus is not in operation. No messages are processed.
The RS bus is in operation. Messages are being processed.
Message-LED
In the current firmware version, this LED has no function.
RS node LED 0 - 7 (each LED is assigned to one of the 8 RS nodes)
ReadyRS is in the "disabled" status. The BiDiB bus is not active.
ReadyRS is in the "enabled" status. The BiDiB bus is active.
The corresponding node has detected a feedback and reported it via BiDiB.
The corresponding node has detected a feedback with parity error and has
NOT reported it via BiDiB.
Power-ON LED, BiDiB-Identify LED, Message-LED
Message-LED, XP-LED
Page 27
2
3
4
5
Technical changes and errors reserved
R
eady
Line
1
© 2022 FichtelBahn®

Advertisement

Chapters

Table of Contents
loading

Related Products for Fichtelbahn ReadyRS

Table of Contents