3.2
PPE characteristics
Electrical safety gloves
Insulating gloves for working on electrical systems, class 00, test
voltage 2500V, operating voltage 500V.
Class III personal protective equipment that complies with the
following standards
European:
International:
Visor
To protect the face from splashes of liquid/solid material and electric
arcs in case of short circuit.
Class III personal protective equipment, complying with European
standards:
EN 166: Personal eye protection - Specifications.
EN 170: Personal eye protection - Ultraviolet filters.
The absence of voltage is detected using a tester.
The measurement must be carried out between the metal chassis
of the vehicle and all 400V (orange) cables that are damaged to
such an extent that direct electrical contact between the tester tip
and the conductive core is possible. If several cables or contacts are
exposed as a result of the damage, the absence of voltage must
also be checked between the concerned points and not only with
reference to the metal chassis of the vehicle.
This instrument must comply with the following standards:
European:
International:
EN 60 903
CEI 60 903
EN 61 243-3
CEI 61 243-3
Safety regulations for working with high
E-DUCATO
voltages
14