9.
Turn Prime/Spray valve down to PRIME
position.
10. Install battery, see Battery Installation
and Removal, page 14.
11. Turn ON/OFF switch to ON position.
Button is illuminated when ON.
12. Flush until approximately 1/3 of the
flushing fluid is emptied from the pail.
13. Turn ON/OFF switch to OFF position.
Button is not illuminated when OFF.
NOTE: Step 14 is for returning paint in hose
to paint pail. One 50 ft (15.2 m) hose holds
approximately 1 quart (1 liter) of paint.
14. To recover paint in hose, point gun into
paint pail while holding gun firmly to the
pail.
a.
Disengage trigger lock (A).
b.
Pull and hold gun trigger (B).
c.
Turn Prime/Spray Valve horizontal
to SPRAY position (C).
d.
Turn ON/OFF switch to ON
position (D). Button is illuminated
when ON.
26
e.
Continue to hold gun trigger until
you see paint diluted with flushing
fluid starting to come out of gun.
15. While continuing to trigger gun, quickly
move gun to redirect spray into waste
pail. Continue triggering gun into waste
pail until flushing fluid dispensed from
gun is relatively clear.
16. Turn pressure control knob to the lowest
setting.
17. Stop triggering gun. Engage the trigger
lock.
18. Turn Prime/Spray Valve down to PRIME
position.
19. Turn ON/OFF switch to OFF position.
Button is not illuminated when OFF.
20. Remove battery, see Battery
Installation and Removal, page 14.
21. Follow Short Term Storage or Long
Term Storage, page 30.