X 1 A
3
X 1 4 Y
4
3 Remove the switch box cover.
4×
T25
4 If necessary, remove the front plate. This is, for example,
necessary in the following cases:
▪
"4.2.2 To lower the switch box on the indoor
▪
"4.3.2 To connect the drain hose to the
▪ When you need access to the high voltage switch box
2×
T25
5 If you need access to the high voltage components, remove the
high voltage switch box cover.
EHVH04+08SU18+23EA
Daikin Altherma 3 R F
4P629088-1C – 2021.11
4.2.2
During the installation, you will need access to the inside of the
indoor unit. To have easier front access, put the switch box lower on
the unit as follows:
Prerequisite: The user interface panel and front panel have been
removed.
1 Remove the fixing plate at the top of the unit.
2 Tilt the switch box to the front and lift it out of its hinges.
unit" [ 4 11]
drain" [ 4 12]
3 Place the switch box lower on the unit. Use the 2 hinges located
4.2.3
1 Close the cover of the switch box.
2 Put the switch box back into place.
4×
T25
To lower the switch box on the indoor unit
2×
T25
1
lower on the unit.
To close the indoor unit
4 Unit installation
Installation manual