IMPORTANT WARNINGS Dear Customer: Thank you for your confidence in us by purchasing this radiator. These appliances are extremely safe, silent and easy to install. They do not require special maintenance. They are made of extruded aluminum, a material of high durability respectful to the environment. Before starting it for the first time, carefully read these instructions.
Page 3
12. Children under the age of three should not be allowed to touch or play with the radiator and should be supervised at all times. 13. This device can be used by children under 8 years of age, as well as by people with reduced physical, sensory or mental capabilities when suitably supervised and only when they have been provided the instructions regarding the use of the device...
21. Do not attempt to service the device yourself. Contact a qualified technician. 22. To disconnect the transmitter from the mains pull the plug, never of the supply cord. 23. Respect the "SPECIFIC SAFETY INSTRUCTIONS FOR THIS APPLIANCE" listed below SPECIFIC SAFETY INSTRUCTIONS FOR THIS DEVICE ...
Allow for a minimum distance of 1 m, from the front of the unit to any obstacles (furniture, walls, curtains, for example) that could hinder its operation. Also keep a minimum distance of 15 cm between the appliance and the side walls and any other obstacles (walls, for example) that may affect its function.
5. Hang the radiator in the supports fixed on the wall and, finally , completely screw up the two security pieces of the supports. ELECTRIC SUPPLY CONNECTION This appliance is equipped with a supply cord H05V2V2-F 2x1.0mm² and bipolar plug without earthing. Connect the plug to the base outlet.
Page 7
Normal: orange light on, alternating with green light every 5 secs. If this is not the case, consult point7. Possible problems and solutions. 4. Register with HJM through the app that can be found on Google play or Apple store.
Page 8
5. Access the app through your account and configure the house’s data, automatically detect the smartbox and then follow the instructions on the screen. PAIRING RADIATORS WITH THE SMARTBOX The radiators have to be paired with the smart box in order to be controllable through the apps.The link indicator will appear on the screen when it is paired.
Page 9
“Link” symbol appears on the radiator screen. The radiator will now be paired with the smart box. Now you can control the radiator programming and the temperatures through the HJM app. You can un pair the radiator from the smart box by resetting the radiator.
Page 10
This device is inserted into the house’s fuse box. The house’s electricity must be switched off before installing it. Connect the device to a 230V power supply. Connect the meter clip and clasp it to the house’s main cable. To pair the meter with the smartbox, once discoverable mode has been activated(as shown on page 9), press the button inside the device with a paperclip or pointed object: Through the app, you will be able to see electricity consumption in real time and be...
Page 11
PROGRAMMABLE DIGITAL THERMOSTAT This radiator is equipped with various functions and operating modes that the user can select through the Modo/OK key. The operating modes are: Auto, Manual and OFF. They can be selected by pressing the Modo/OK key. SCREEN 11/24 HJM_RFC_WIFI_ENG_Rev.0_13-11-2018 Made in Spain...
1. ON / OFF (STAND-BY) To turn the radiator on, press the Modo/OK key and select AUTO mode or MANUAL mode. To turn the radiator off (stand-by), press the Modo/OK key and select OFF mode. 2. SETTING THE TIME In the event that the device is already paired with a smart box, the time setting is annulled and the time in the smart box is configured automatically.
Page 13
Pressing the keys we can select the current hour. Press the key to confirm the selection and go to the next screen, in which the minutes start flashing. Change the value pressing the keys. Press the key to confirm the selection and it will automatically go to the mode it was in before.
Page 14
Press the key and you will go to the screen where you can change the comfort temperature . Press the keys to change to the desired comfort temperature. Once you have selected it press the key and you will then be able to select the economic temperature ;press the keys to change to the desired economic temperature.
The first time band will be flashing, it corresponds to 00:00 on day 1 (Monday). By default, the Economic temperature level is selected for all time bands. You can change the type of temperature (comfort, economic or frost protection), pressing the key.
Page 16
5.2. -C2: Control type setting C2: Setting the type of control (PID-equipment with TRIAC-, PID15min or PID30min- relay equipment, hysteresis of 0.25ºC, 0.35ºC, 0.5ºC, 0.75ºC). To access the advanced configuration menu, press the key. The following window will be displayed. Press the again for 5 secs and you will access the first advanced parameter (C1), which will be displayed on the screen, flashing.
5.5.- C5: Open window detection The radiator has the option to activate open window detection. By activating this parameter, the radiator automatically disconnects when it detects a drop in temperature in the room caused by the opening of a window or similar. This means that when the temperature in the room drops 2,4ºC in 4 minutes, the radiator will disconnect for 30 minutes.
Orange on and alternates with green every 5 secs.:smart box with IP and communication with server. 2) Equipment does not communicate with the smart box: Make sure that the equipment is previously paired with your smart box. The Link icon appears static on the screen.
Without paired RF network Temperature units: ºC Open window protection: deactivated Control mode: PID Default programme: All Eco 9. RESET THE RADIATOR To reset the radiator, press the keys together for 10 secs. The "rES" message will appear on the screen.
Page 20
EU Declaration of Conformity Ceramic Heater WIFI Product: Trademark: Models: RFC500W; RFC1000W; RFC1500W & RFC2000W Batch & Serial No.: Mx- YYDDD-XXX (1) Explanation of code "Batch & Serial No.": Batch = Mx - YYDDD; where: Mx = Production Line No.; YY = year and DDD = correlative day (001,..., 365).
Page 21
Model: RFC Item Value Unit Item Unit Symbol Type of heat output/room Heat output temperature control (select 2000 one) single stage heat Nominal heat output output and no room temperature control Two or more manual Maximum continuous stages, room max,c heat output temperature control with...
Page 22
Heat output with black bulb sensor 1000 Nominal heat output Maximum continuous max,c heat output Auxiliary electricity consumption At nominal heat output 0.0005 In standby mode Heat output Nominal heat output Maximum continuous max,c heat output Auxiliary electricity consumption At nominal heat output 0.0005 In standby mode HERMANOS JULIÁN M., S.L.
Page 23
= - 10% + F(1) + F(2) + F(3) - F(4) - F(5) S,on = 40 -10%+0+7+2-0-0 = 39% RECYCLING (Disposal of the product at the end of its useful life) According to European Directive 2012/19/UE, on waste electrical and electronic equipment (WEEE), old electrical household appliances cannot be disposed of in the usual municipal containers;...
Page 24
Made by HERMANOS JULIAN M., S.L. Factory: Gutenberg,91-93 Polígono Industrial “Los Villares” ES-37184 Villares de la Reina . Salamanca . Spain +34 923 222 277 - +34 923 222 282 Fax: +34 923 223 397 Web: www.calorhjm.es ESB-37295664 24/24 HJM_RFC_WIFI_ENG_Rev.0_13-11-2018 Made in Spain...
Need help?
Do you have a question about the RFC Series and is the answer not in the manual?