Page 1
ORIGINAL OPERATING INSTRUCTIONS Read carefully and retain for future reference Ceramic Heater Reference RFCS 1/21 HJM_RFCS_ENG_Rev.1_30-11-2017 Made in Spain...
IMPORTANT WARNINGS Dear Customer: Thank you for your confidence in us by purchasing this radiator. These appliances are extremely safe, silent and easy to install. They do not require special maintenance. They are made of extruded aluminum, a material of high durability respectful to the environment. Before starting it for the first time, carefully read these instructions.
Page 3
12. Children under the age of three should not be allowed to touch or play with the radiator and should be supervised at all times. 13. This device can be used by children under 8 years of age, as well as by people with reduced physical, sensory or mental capabilities when suitably supervised and only when they have been provided the instructions regarding the use of the device...
21. Do not attempt to service the device yourself. Contact a qualified technician. 22. To disconnect the transmitter from the mains pull the plug, never of the supply cord. 23. Respect the "SPECIFIC SAFETY INSTRUCTIONS FOR THIS APPLIANCE" listed below SPECIFIC SAFETY INSTRUCTIONS FOR THIS DEVICE The appliance must remain in a vertical position.
Allow for a minimum distance of 1 m, from the front of the unit to any obstacles (furniture, walls, curtains, for example) that could hinder its operation. Also keep a minimum distance of 15 cm between the appliance and the side walls and any other obstacles (walls, for example) that may affect its function.
ELECTRIC SUPPLY CONNECTION This appliance is equipped with a supply cord H05V2V2-F 2x1.0mm² and bipolar plug without earthing. Connect the plug to the base outlet. Check the condition of your electrical installation and connection cables. This appliance doesn't require earthing connection, due it has double electrical insulation.
Page 7
PROGRAMMABLE DIGITAL THERMOSTAT This radiator is equipped with various functions and operating modes that the user can select using the “MODE” button. The operating modes are: Pilot Wire, Comfort, Economy, Anti-Frost, Holidays, Timer, Turbo, Eco and Off (Stand-by). These are their related icons: ...
Page 8
Other thermostat functions are: • Other functions and icons Open window detection: This function allows us to detect that a window is open due to a sudden drop in room temperature. In this case, the device stops feeding the resistance for a maximum of 30 minutes or until an abrupt increase in room temperature shows that the window has been closed.
Page 9
SCREEN 1. ON / OFF (STAND-BY) Press the On/Off (Stand-by) button to turn the radiator on or to set the off/stand-by mode. If the off/stand-by mode is activated, the corresponding icon will appear on the screen and there will be two 0.5 second bleeps and the time will be shown. When the device is turned on, there will be a one second bleep and the icon will disappear.
2. MAIN FUNCTIONS PILOT WIRE Mode: (FOR USE IN FRANCE ONLY). In this mode, the radiator is controlled by a unit with this type of system. In order to activate it, follow these steps: 1. Press the “Mode" button several times until the icon appears on the screen.
Page 11
it. When operating, it is possible to change the temperature easily by pressing the buttons. ANTI-FROST MODE: Selecting this mode, the room temperature is set at 7°C. In order to activate it, press the “Mode" button several times until the icon appears on the screen.
Page 12
TURBO/BOOST MODE: This mode can be used when we need to heat the room quickly. In order to activate it, follow these steps: 1. Press the “Mode" button several times until the icon appears on the screen. Pressing the buttons it is possible to select the TURBO/BOOST period duration from 5 to 120 minutes.
Page 13
To select this mode, press the “Mode" button several times until the icon appears on the screen. 3. OTHER FUNCTIONS AND ICONS OPEN WINDOW DETECTION: The radiator is able to detect if a window has been opened through a sudden drop in temperature (5°C in a maximum of 30 minutes). If this happens, the device disconnects for 30 minutes so as to, later on, operate again at the previously established mode if it detects continuous increases in temperature of one degree (because, for example, the window has been closed).
Page 14
POWER LEVEL INDICATOR: This appears on the left-hand side of the screen and it depends on the programmed temperature level. The higher the programmed temperature is, the greater the number of bars shown on the icon. This is instantaneous consumption visualisation as, the higher the programmed temperature is, the higher the energy consumption is.
Page 15
2. Press the button for more than 3 seconds until the consumption data is shown on the screen. 3. Using the buttons, we can scroll the consumption menu. 4. The icons will appear on the right-hand side of the screen. Each one shows the consumed kWh during the corresponding period of time, as shown here: = current day = previous day...
Page 16
4. PROGRAMMING DAY AND TIME PROGRAMMING 1. Turn the radiator to off/stand-by mode. The icon will be shown. 2. Press the button for more than 3 seconds until the functions can be seen. Using the button you can scroll through the following options: “ted”(hour and date), “prog”(programming) and “ofst”(calibration of the temperature sensor).
Page 17
5. Pressing the button we select the COMFORT mode in this time interval (the whole interval will be highlighted). Pressing the button we select the ECONOMY mode for this time interval (half an interval will be highlighted). And so on until completing the 24 hours of day 1=Monday. Confirm the programming with the button.
Page 18
4. With the buttons establish the temperature difference between the room temperature (measured with a thermometer) and the temperature detected by the radiator. This difference can be adjusted between -5°C and +5°C. 5. Press the button to confirm the selection. ACTIVATING OTHER FUNCTIONS OPEN WINDOW DETECTION 1.
THERMAL SAFETY In the case of overheating, a safety device automatically cuts the radiators operation. After cooling the radiator will automatically reset. MAINTENANCE Your radiator requires no regular maintenance, however, to ensure its good operation: Always disconnect the device from the mains before performing any cleaning or maintenance operation.
Page 20
EU Declaration of Conformity Product: Ceramic Heater Trademark: RFCS Models: RFCS1000 (230V 50Hz; 1000W; IP24; Class II) RFCS1500 (230V 50Hz; 1500W; IP24; Class II) Types: RFCS2000 (230V 50Hz; 2000W; IP24; Class II) Mx- YYDDD-XXX Batch & Serial No.: (1) Explanation of code "Lot & Serial No.": Lot = Mx - YYDDD; where: Mx = Production Line No.; YY = year (15,16,17...99) and DDD = jour corrélative (001,..., 365).
Page 21
RECYCLING (Disposal of the product at the end of its useful life) According to European Directive 2012/19/UE, on waste electrical and electronic equipment (WEEE), old electrical household appliances cannot be disposed of in the usual municipal containers; they have to be collected separately to optimise the recycling of the components and materials that comprise it, and reduce the impact on human health and the environment.
Need help?
Do you have a question about the RFCS and is the answer not in the manual?
Questions and answers