MAINTENANCE
AIR FILTER INSTALLATION
1. Remove the seat, the air box cover strap, and remove the air box cover.
2. Remove the filter.
3. Remove the fabric type pre- filter from the main filter. Wash the pre-filter in
soapy water, then rinse and let dry.
4. Reinstall the pre-filter over the main filter. Install a new main filter if needed.
5. Reinstall the filter into the air box.
6. Reinstall the air box cover and the seat.
FUSE REPLACEMENT
If the engine stops or will not start, or if you experience other electrical failures, a
fuse may need replacement. Locate and correct any short circuits that may have
caused the blown fuse, then replace the fuse.
Spare fuses are provided in the fuse box.
1. Access the fuses under the front box.
2. Remove the fuse box cover.
3. Remove the suspect fuse from the fuse panel. If the fuse is blown, install a
new fuse with the same amperage rating.
4. Reinstall the fuse box cover.
5. Close and secure the front box and cover.
SCRAMBLER® XP 1000
SPARE
20A
SPARE
20A
START
RELAY
104
Downloaded from
ManualsNet.com
UN-
FAN CKT
SWITCH-
BKR
ED
20A
10A
ACCES-
EPS
SORY
30A
20A
EPS
SPARE
RELAY
30A
search engine
FUEL
EFI
PUMP
10A
10A
DRIVE
LIGHTS
20A
20A
FUEL
FAN
PUMP
RELAY
RELAY
CHASSIS
RELAY
EFI
RELAY