LS190
Gloss Meter
User Manual V1.1
Please read this manual carefully before using and reserve it for reference.
October 9, 2021
Page 1 of 7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LS190 and is the answer not in the manual?

Questions and answers

Summary of Contents for LINSHANG LS190

  • Page 1 Shenzhen Linshang Technology Co., Ltd. LS190 Gloss Meter User Manual V1.1 Please read this manual carefully before using and reserve it for reference. October 9, 2021 Page 1 of 7...
  • Page 2 Shenzhen Linshang Technology Co., Ltd. I. Product Introduction The instrument is a hand-held gloss meter for professional surface gloss test on paint, coating, ink, plastic, paper, ceramic, stone, metal and electroplating layer, etc. The instrument is easy to use, put and measure, no need to press the button.
  • Page 3 Shenzhen Linshang Technology Co., Ltd. Working Temperature 10~45 °C, 0~85%RH (no condensation) Storage Temperature -10~60 °C,0~85%RH (no condensation) III. Features Real-time and put-and-measure services. Detect samples quickly with the QC judging function. The environmental temperature compensation function guarantees long-term calibration stability.
  • Page 4 Shenzhen Linshang Technology Co., Ltd. 3. Calibration If the meter gets powered on in the calibration holder, it will enter the calibration interface. The user can perform the calibration operation according to the prompts, the instrument will enter the measurement interface after the calibration.
  • Page 5 Shenzhen Linshang Technology Co., Ltd. (2) QC Mode If the instrument is set to QC mode, remove the calibration holder after calibration, place the measuring port of the instrument on the surface of the object to measure, short press the button to measure, the instrument will judge whether the measured value is qualified.
  • Page 6 Shenzhen Linshang Technology Co., Ltd. VI. Precautions 1. The temperature compensation function guarantees long-term calibration stability, it is recommended to calibrate once a week. If the environmental temperature changes significantly, please recalibrate 2. The measuring port of the instrument shall be attached to the surface of the object to avoid leakage of external light.
  • Page 7 2. Provide users with spare parts and lifelong maintenance services. 3. Provide the users with the gauge calibration service. 4. Provide long-term free technical support. Manufacturer: Shenzhen Linshang Technology Co., Ltd. Website: www.linshangtech.com Service hotline: +86-755-86263411 Email: sales21@linshangtech.com...