✔ After the air conditioning service has finished, you will be prompted to
disconnect the hoses (10) and (11) of the A/C service unit from the
vehicle air conditioning system.
10. Disconnect the service hoses (10) and (11) and press ENTER to
confirm.
The service hoses will now be drained. The device is then ready for
further use.
11. Put the valve caps of the vehicle air conditioning system back on the
connections.
9.3

User codes

It is possible to protect the air conditioning service station from unautho-
rised access using personal user codes. When this function is activated,
the system queries the user code after being switched on, and the station
cannot be started without it. Up to 10 different users can be created, each
with individual codes.
9.3.1
Creating user codes
1. In the basic menu, use the cursor keys  or  to select "Other
selections":
2. Press ENTER to confirm.
3. Use the cursor key  to select "Service" and press ENTER to
confirm:
4. To access the "ADM" administrator menu, enter the password
"9786" and press ENTER to confirm:
5. Enter the administrator code "0000" (default setting) and press
ENTER to confirm: