12. Connect the components for flushing to the service ports (12)
and (13) of the A/C service unit using special adapters and in accor-
dance with the manufacturer's specifications to form a flushing cir-
cuit.
13. In the basic menu, use the cursor keys  or  to select "Other
selections":
14. Press ENTER to confirm.
15. Use the cursor keys  or  to select "Flushing":
16. If necessary, use the keypad (7) to enter the data and press ENTER
to confirm. If no data is to be entered, press ENTER to switch to the
next program step.
17. Use the cursor keys  or  to select whether to flush the entire air
conditioning system or just individual components:
18. Press ENTER to confirm.
19. Follow the instructions in the display.
✔ After flushing is completed, the basic menu for the A/C service unit
appears.
20. If necessary, remove the adapter from the flushing circuit and
reconnect all the components to the refrigerant circuit.
Fit the connections of the A/C service unit to the vehicle air
conditioning system and open them.
21. In the basic menu, use the cursor keys  or  to select "Free
selection":
22. Press ENTER to confirm.
23. If necessary, use the keypad (7) to enter the data and press ENTER
to confirm.
If no data is to be entered, press ENTER to switch to the next
program step.
EN
Short selection
Free selection
Other selections
ENTER-OK
Flushing
Reset scales.
Service.
ENTER-OK STOP-EXIT
Full flushing
Fast flushing
ENTER-OK STOP-EXIT
Short selection
Free selection
Other selections
ENTER-OK
Operation
105